PAGE 2 OF 4
PRINTED IN USA
MFG. #5401060 - REV H
5/02
ADPS
ADJUSTABLE DEADBAND
PRESSURE SWITCH
MOUNTING AND INSTALLATION
The Model ADPS is typically mounted in an upright position on a flat surface by two 1/4" screws
through the mounting flanges on the base or by two 1/4-20 screws into the back of the base.
See Fig. 1 for mounting dimensions. Locate the switch where vibration, shock and ambient
temperature fluctuations are minimal. To avoid damage to the switch, always hold a wrench
on the pressure connection hex when tightening pressure connections. Never tighten the
pressure connection by turning the switch housing into the fitting.
FIG. 1
WIRING
Use properly rated temperature supply wire for the anticipated service temperature. Make all
electrical connections in accordance with the National Electrical Code and local regulations.
A wiring check may be performed by manually actuating the switch actuator on the side of the
snap-action switch inside the enclosure. (See Fig. 3)
NOTE:
Do not loosen or remove the two (2)
screws that secure the switch to the switch mounting bracket.
4.47
.88
1.66
3.26
5.41
2.25
1.33
DWG. #1080-1
(2)
1
4
-20 x .50 DEEP
THREADED HOLES FOR
BACK MOUNTING OPTION
(1) Ø.875 HOLE
FOR
1
2
" CONDUIT
CONNECTION
3.38
(2) Ø.266 MOUNTING
THRU HOLES
FOR
1
4
" SCREWS
.94
4.65
COM.
N.C.
N.O.
N.O.
N.C.
COM.
DWG. #1060-2
SWITCH ACTION ON
(OPERATING POINT)
HIGH PRESSURE
(RESET POINT)
LOW PRESSURE
SWITCH ACTION ON
N.C.
N.O.
COM.
N.C.
N.O.
COM.
FIG. 2