POSX xi3000 Скачать руководство пользователя страница 6

 

5

 

2.4.3

 

DC Jack 

                                                   

        

Insert the power supply to the DC Jack at bottom of the scanner. When charging, 
the scanner LED will flash RED. When the battery is fully charged, around 4 hours 
from completely empty battery, the LED stays on solid RED.  

 

2.5

 

Interface Setting 

 

Once you have “paired” the scanner and base, you need to specify the interface 
type to your PC. The interface settings are stored in the base. So ensure that you 
have RF connection between your scanner and base prior to setting the interface 
type. For details on selecting interfaces please refer to the relevant section in this 
manual. 

 

 

 

6

3.

 

General Features 

3.1

 

Buzzer 

 

The buzzer of the scanner beeps differently to indicate various operating 
conditions. 

 

Power On Beep

: The scanner will issue a long beep to indicate a successful 

power on. 

 

Good Read Beep

: The system provides four volume levels and four beeping 

tones (frequencies) that the user can select from to signify a good read. The 
available options are: 

Volume: Maximum/Loud/Medium/Minimum 
Frequency: 8 / 4 / 2 / 1 kHz 

 

Error Beep

: The scanner will issue a long beep with a low tone to indicate 

errors. 

 

Enter / Exit Configuration Beep

: The scanner will issue 6 beeps upon entering 

/ exiting the configuration mode. 

 

Setup Beep

: In configuration mode, the scanner will normally beep twice when a 

setup barcode is read. If the particular setup parameter needs more than one read, 
the scanner will only issue a short beep to indicate that there are more setup 
barcodes needed to complete the current parameter setting. 

3.2

 

Indicator 

 

There is a dual color indicator on top of the scanner. Normally it is off, and will 
turn red when there is a good read. The indicator will be blue when the scanner is 
at configuration mode. 

3.3

 

Scan Modes 

 

There are eight scan modes supported by the scanner. The user can choose the 
desired scan mode depending on the application requirements. But, if the scanner is 
a trigger-less scanner, only continuous mode or testing mode can be selected (other 
scan modes involve trigger switch interaction). The supported scan modes are 
described below. 

 

Auto Off Mode:

  The scanner will start scanning once the switch is 

triggered. The scanning continues until either a barcode is read or a preset 
scanning period (

Scanner Time-Out Duration

) is expired.

 

Содержание xi3000

Страница 1: ...and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help If applicable as...

Страница 2: ...uffer Setting 13 4 4 2 Memory Mode 13 4 4 3 Clear Data 13 4 4 4 Send Data 13 4 4 5 Memory Data Delay 13 5 BLUETOOTH SERIAL PORT 14 5 1 CONFIGURING Xi3000 BT 14 5 1 1 Activate Bluetooth Serial Port Int...

Страница 3: ...OF FIELDS 38 9 5 DIVIDING DATA INTO FIELDS 38 9 6 ADDITIONAL FIELDS 39 9 7 FIELD TRANSMISSION SEQUENCE 39 9 8 END OF FORMAT PROGRAMMING 39 9 9 ACTIVATE DATA EDITING FORMATS 39 9 10 EXCLUSIVE DATA EDI...

Страница 4: ...on Bluetooth HID Supported The scanner can transmit scanned data to Bluetooth enabled computer PDA via standard HID communication Programmable Code ID Code ID can be individually configured for each s...

Страница 5: ...TION barcode label the scanner will beep once then scan the SERIAL number barcode The scanner will beep twice low then high beep When it establishes RF connection with the base the scanner will then e...

Страница 6: ...eep The scanner will issue a long beep with a low tone to indicate errors Enter Exit Configuration Beep The scanner will issue 6 beeps upon entering exiting the configuration mode Setup Beep In config...

Страница 7: ...code is brought within Range of the scanner This will activate the LEDs and the scanner will start decoding the barcode The auto sense mode works only under Auto Off mode or Laser mode only 8 3 5 Re r...

Страница 8: ...below PCAT US French German Italian Swedish Norwegian UK Belgium Spanish and Portuguese KBD PS2 30 IBM 3477 TYPE Japanese KBD IBM 34XX 319X Memorex Telex 122Keys 4 1 2 Keyboard Style Alphabets Keyboar...

Страница 9: ...232 Interface User can select the desired flow control baud rate parity and data bits to be used in this output interface 4 2 1 Baud Rate Parity Data Bits The supported baud rate parity and data bit a...

Страница 10: ...ction illustrates a step by step installation and configuration procedures of the Xi3000 BT for Bluetooth Serial Port Bluetooth transceivers dongles always come with their own driver or Windows XP wit...

Страница 11: ...the connection is closed when the host application closes the COM port After the connection is closed the scanner will again wait for new connection request for one minute before it goes to power dow...

Страница 12: ...y Computer 2 Double click the My Bluetooth Places at left Folders window Right click My Device and select Property 18 3 Select Client Applications tab and select Bluetooth Serial Port from the list th...

Страница 13: ...Connection is enabled another window might pop up and asking for PIN code 8 Click OK button After successful connection the Bluetooth Device Driver will report the COM port number which is mapped for...

Страница 14: ...eral Bluetooth device drivers for Windows and WinCE Pocket PC from different companies Here we use Window XP with service pack2 build in Bluetooth driver and WIDCOMM driver as examples For detail inst...

Страница 15: ...canner will make necessary adjustment when sending the A Q W Z Y and M character according to this setting 6 2 3 Keyboard Style Digits There are two digit layout styles as shown on the following figur...

Страница 16: ...ections 6 3 1 Windows XP with Service Pack2 1 Insert the Bluetooth dongle into PC host 2 Double click the Bluetooth icon on the lower right of the taskbar 3 Click Add button 4 Check My device is set u...

Страница 17: ...mm Bluetooth Driver 1 Click icon at PC 2 Click Find Bluetooth Devices icon at My Bluetooth Places 28 3 Right click the Xi3000 BT scanner and select Pair Device 4 Input PIN code and click OK button 5 R...

Страница 18: ...g transmitted 7 2 Italy French Pharmacode For Italy French Pharmacode there is always a checksum character included in the barcode So the checksum verification is always performed when decoding these...

Страница 19: ...ng Because of the way system number 1 is encoded if both system numbers are enabled user might suffer from short scanning UPCA or EAN13 into UPCE system number 1 barcodes Convert to UPCA If this param...

Страница 20: ...selected the max length and the min length must be specified and the scanner will only accept those codes with lengths fall between max min length specified 7 10 Plessey Convert to UK Plessey If this...

Страница 21: ...ngth Code or any Additional Field and is performed before editing mode processing If only the character to be replaced is specified every occurrence of that character in the barcode will be taken away...

Страница 22: ...not be performed unless all three applicable conditions are met The configurable applicable conditions are described below Code Type This parameter specifies the code type of the data eligible for dat...

Страница 23: ...n the Editing Format Parameters section of the configuration manual 9 9 Activate Data Editing Formats Before data can be processed by a particular editing format that format must be enabled The editin...

Страница 24: ...r most of the parameters only one read is required to set them to new values The scanner will respond with two beeps when these parameters are configured But for some special parameters multiple reads...

Страница 25: ...are the scan code value of the character being programmed Add Shift The Shift key will be sent together with the character programmed 44 Add Control L The left Control key will be sent together with t...

Отзывы: