PostProcess Technologies, Inc. • www.postprocess.com • REV C | page 9
1. OPERATION
1.3.5 Selecting the Temperature Unit of Measure
1.3.6 Selecting the Degas Time
The CENTI is capable of displaying the tank temperature in Fahrenheit (˚F) or Celsius (˚C). To set the temperature
unit, press the
Fn
button four times or until the temperature icon is blinking. Press the
UP
arrow for temperatures
to be displayed in Fahrenheit or the
DOWN
arrow for the readings to be in Celsius. The temperature readings are
located at the left side of the
Control
screen as shown below. In the example shown the temperature units are
displayed in Fahrenheit.
The CENTI has built-in Degas functionality to remove excess gasses from fluids. For further information see
Section 1.4.1 - Degas Procedures
. To set the timer for a Degas cycle press the
Fn
button
five times or until the
Degas icon begins flashing. The
Degas
icon will display and the time clock and minute counter will begin flashing.
Press the
UP
or
DOWN
arrow to scroll to your desired time in minutes from 1 to 99.