Positron GAM-4-CRX Скачать руководство пользователя страница 6

GAM Quick Installation Guide 

 

 

Positron Access Solutions 

Document 180-0212-001 R02 

1.1 

Introduction 

The  GAM  is a  Fiber  to  the  Distribution  Point  (FTTDp)  solution  typically  installed 
inside  a  wiring  closet.  The  GAM-4-CRX  and  GAM-4-CX  come  with  one  (1)  10 
Gigabit SFP+ interfaces to support any type of fiber or PON standards (using an 
SFP-based or external ONT as required that is compatible with the OLT). 

The ITU-T G.9960 G.hn Wave-2 standard leverages the existing telephone wiring 
(UTP,  CAT-3  or  CAT-5/5e)  or  RG-6/RG-59  coax  cabling  to  deliver  a  Gigabit 
Internet  service  to  each  subscriber  without  the  cost,  complexity  and  delays 
associated  with  in-building  fiber  installation.  G.hn  is  an  Access  technology  for 
Operators looking to simplify their access network and backend infrastructure with 
an  Ethernet-like  technology  that  is  highly  scalable  without  some  of  the  inherent 
complexity  of  DSL-related technologies.  With  G.hn,  Operators deliver  advanced 
services such as Gigabit High Speed Residential Internet and 4K IPTV without the 
high capital and operational expenses associated with a fiber retrofit.  Each G.hn 
subscriber  port  supports  up  to  1.7  Gbps  of  dynamically  allocated  bandwidth  for 
near  symmetrical  Gigabit  services  over  the  existing  telephone  wire  or  coaxial 
cable. The Positron GAM solution is MEF CE 2.0 compliant and is ideally suited to 
deliver Business Ethernet services in an MDU and/or MTU deployment. 

Note:

  Read Chapter 4 Safety and Warnings before proceeding.  

1.2 

GAM Connections 

This section provides an overview of the connectors inside the GAM-4-CRX and 
GAM-4-CX.    Please  refer  to  section  2  for  a  detailed  step-by-step  installation 
procedure. 

1.2.1 

Power Connection 

The GAM-4-CRX is Reverse Power Fed (from G1001-CR endpoint devices) while 
the  GAM-4-CX  is  locally  powered.    There  must  be  at  least  one  (1)  G1001-CR 
device  per  G.hn  coax  port  of  a  GAM-4-CRX  that  is  serving  customers.    Other 
subscribers can then use a G1001-CR or a G1001-C/G1000-C as needed. 

Содержание GAM-4-CRX

Страница 1: ...G hn Access Multiplexer GAM Quick Installation Guide GAM 4 CRX GAM 4 CX...

Страница 2: ...a Published By Positron Access Solutions 5101 Buchan Street Suite 220 Montreal Quebec Canada H4P 2R9 Telephone US and Canada 1 888 577 5254 International 1 514 345 2220 Product names other than Positr...

Страница 3: ...ts 8 1 2 5 GAM LED Indicators 9 1 2 6 GAM Reset Button 11 Chapter 2 12 Step by Step Installation 12 2 1 Step by Step Installation Procedure 13 Chapter 3 19 WEB Management 19 3 1 Introduction 20 3 2 Sy...

Страница 4: ...THE GAM CIRCUITRY 8 FIGURE 5 GAM SERIAL MANAGEMENT PORT PINOUT 9 FIGURE 6 GAM GLOBAL STATUS LEDS 9 FIGURE 7 G HN PORTS LEDS 10 FIGURE 8 SFP LED 10 FIGURE 9 GAM RESET RST BUTTON 11 FIGURE 10 GAM LOGIN...

Страница 5: ...GAM Quick Installation Guide Positron Access Solutions 5 Document 180 0212 001 R02 Chapter 1 ______________________________________ About the GAM...

Страница 6: ...f DSL related technologies With G hn Operators deliver advanced services such as Gigabit High Speed Residential Internet and 4K IPTV without the high capital and operational expenses associated with a...

Страница 7: ...GAM SFP Connectors The GAM has one 1 SFP ports that support any MSA compliant SFP SFP modules Fiber 1G 10G and Copper RJ 45 100M 1G Important note When connecting the SFP port to a Passive Optical Ne...

Страница 8: ...ement ports located near the top right corner of the enclosure Figure 4 Local Management Ports are at the top right corner of the GAM circuitry The CRAFT port is a standard serial V 24 115200 8 N 1 po...

Страница 9: ...M uses three 3 LED indicators inserted in the cover of the IP67 enclosure to provide information about its global status and operating mode Figure 6 GAM global status LEDs LED Condition Function RPF O...

Страница 10: ...of the Reverse Power Feed source from a G1001 CR device at the customer end LED Condition Function G hn ports Off Blinking On Disabled or Link Down Bad or low speed G hn link Link is Up G hn port pow...

Страница 11: ...is Up Link Activity Table 3 SFP LED indicator 1 2 6 GAM Reset Button Press the RST button to reset the GAM When depressed for two 2 to ten 10 seconds it will perform a cold reboot of the GAM When depr...

Страница 12: ...GAM Quick Installation Guide Positron Access Solutions 12 Document 180 0212 001 R02 Chapter 2 ______________________________________ Step by Step Installation...

Страница 13: ...ecting the AC DC Power supply included as part of your GAM 4 CX You should skip this step if you are using a Reverse Power Fed GAM 4 CRX unless you plan to temporarily power the GAM for a temporary 12...

Страница 14: ...iver Step 3 insert the male power connector into the female receptacle You can now connect the other end of the 12Vdc 4A adapter to the local 110 220VAC power source The next step is the insertion of...

Страница 15: ...ugh length to reach the SFP cage while routing the fiber cable above the 2 x RJ 45 ports at the top right of the GAM enclosure Step 6 insert the fiber connectors into the SFP SFP module Note while an...

Страница 16: ...16 Document 180 0212 001 R02 You are now ready to install the ground wire into the ground lug at the bottom right edge of the GAM enclosure Step 8 insert the 6 AWG ground wire into the ground lug Ste...

Страница 17: ...left top left bottom right You can now connect the coaxial cable s to the F type COAX connectors of the unit Step 11 remove the protective cap on the F type connector s where you will attach a coaxial...

Страница 18: ...1 R02 Step 13 the top and bottom brackets are identical Using the Phillips screws supplied with the unit to fasten the bracket on the back side of the enclosure Step 14 Once both brackets are attached...

Страница 19: ...GAM Quick Installation Guide Positron Access Solutions 19 Document 180 0212 001 R02 Chapter 3 ______________________________________ WEB Management...

Страница 20: ...1 Logging into the WEB GUI The default configuration values of the GAM devices are IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Username admin Password Table 4 GAM default credentials Enter the s...

Страница 21: ...inistration Interface pre installed by Positron with one from your preferred Certificate Authority Note Secure HTTP is disabled by default HTTPS can be enabled via menu Configuration Security Switch H...

Страница 22: ...GAM Quick Installation Guide Positron Access Solutions 22 Document 180 0212 001 R02 Chapter 4 ______________________________________ Technical Specifications...

Страница 23: ...tification IEC 62368 1 Electromagnetic Compatibility EN 55032 FCC Part 15 Class A Other mark CE Operating Temperature 40 C to 65 C Storage Temperature 40 C to 70 C Operating Humidity Up to 95 relative...

Страница 24: ...P or G hn ports VLAN Supports up to 4K VLANs simultaneously out of 4096 VLAN IDs Port based VLAN IEEE 802 1Q tag based VLAN IEEE 802 1ad Q in Q double tag VLAN MAC based VLAN Management VLAN Private V...

Страница 25: ...s code point DSCP IP precedence TCP UDP source and destination ports 802 1p priority Ethernet type Internet Control Message Protocol ICMP packets IGMP packets TCP flag Quality of Service Hardware Prio...

Страница 26: ...MON Embedded RMON software agent supports RMON groups 1 2 3 9 history statistics alarms and events for enhanced traffic management monitoring and analysis IPv4 and IPv6 Dual Stack Coexistence of both...

Страница 27: ...GAM Quick Installation Guide Positron Access Solutions 27 Document 180 0212 001 R02 Chapter 4 ______________________________________ Safety and Warnings...

Страница 28: ...Only qualified personnel should service this system All wiring external to the product should follow the local wiring codes Use of this product in a manner other than defined in this installation gui...

Страница 29: ...iring Connection to these ports should be for temporary use during installation or maintenance THIS PRODUCT IS SUITABLE FOR MOUNTING ABOVE GROUND OR UNDER GROUND AT A MAXIMUM DEPTH OF 3 FEET THE UNIT...

Страница 30: ...GAM Quick Installation Guide Positron Access Solutions 30 Document 180 0212 001 R02 Chapter 5 ______________________________________ Warranty and Customer Service...

Страница 31: ...y information can be found in your Positron Access customer web portal http www positronaccess com Portal php Positron Access Solutions Sales Pricing Availability and Technical Support US and Canada 1...

Отзывы: