background image

GAM Quick Installation Guide 

 

 

Positron Access Solutions 

24 

Document 180-0212-001 R02 

Point-to-point and  
Point-to-multipoint 
Support 

Point-to-point (coax) 
Point-to-multipoint operation (coax) for up to 16 Subscriber CPEs per G.hn port 

Ease of Operation  

Supports firmware and configuration management of G.hn end-point devices 

Encryption 

AES-128 encryption with individual keys for each End Point. The Positron GAM Domain 
Master is also acting as the G.hn Security Controller 

Modulation and 
Frequency Band 

Supports OFDM 200 MHz. 
Radio Band Notching function allows cohabitation with legacy analog cable TV channels 
on coax cabling  

Bandwidth 
Management 

Up to 1.7 Gbps with Dynamic Bandwidth Allocation to optimize throughput based on 
nature of traffic flows with TDD Multiplexing for programmable upstream / downstream 
ratio 

Reliability and 
Resiliency 

State of the art LDPC Forward Error Correction (FEC) 

Layer 2 Switching 

 

Spanning Tree Protocol 
(STP)

 

Standard Spanning Tree 802.1d 

 

Rapid Spanning Tree (RSTP) 802.1w 

 

Multiple Spanning Tree (MSTP) 802.1s

 

MAC Table 

Up to 32K MAC addresses 

Trunking

 

Link Aggregation Control Protocol (LACP) IEEE 802.3ad for any SFP+ or G.hn ports

 

VLAN

 

Supports up to 4K VLANs simultaneously (out of 4096 VLAN IDs) 

 

 

Port-based VLAN

 

 

IEEE 802.1Q tag-based VLAN

 

 

IEEE 802.1ad (Q-in-Q) double tag VLAN

 

 

MAC-based VLAN

 

 

Management VLAN

 

 

Private VLAN Edge (PVE)

 

Generic VLAN 
Registration (GVRP)

 

Protocols for automatically propagating and configuring VLANs in a Multicast Domain for 
IPTV and other multicast services

 

IGMP v1/v2/v3 
snooping

 

IGMP limits bandwidth-intensive multicast traffic to only the requesters 
Supports 1024 multicast groups

 

IGMP Proxy

 

IGMP snooping with proxy reporting or report suppression actively filters IGMP packets to 
reduce load on the multicast router

 

IGMP Query 

IGMP query is used to support layer-2 multicast domain in the absence of a multicast 
router 

MLD v1/v2 snooping

 

Deliver IPv6 multicast packets only to the required receivers

 

DHCP Server 

Supports DHCP server to assign addresses to IPv4 client devices 

DHCP Snooping

 

DHCP snooping provides security by filtering un-trusted DHCP messages and by building 
and maintaining a DHCP snooping binding table

 

DHCP Relay 

By supporting DHCP option 82, it is possible to forward DHCP requests to another 
specific DHCP server via DHCP relay. The DHCP server may be on another network 

Layer-3 Support

 

IPv4 Static Routing

 

Static routing of IPv4 unicast traffic

 

IPv6 Static Routing

 

Static routing of IPv6 unicast traffic

 

Содержание GAM-4-CRX

Страница 1: ...G hn Access Multiplexer GAM Quick Installation Guide GAM 4 CRX GAM 4 CX...

Страница 2: ...a Published By Positron Access Solutions 5101 Buchan Street Suite 220 Montreal Quebec Canada H4P 2R9 Telephone US and Canada 1 888 577 5254 International 1 514 345 2220 Product names other than Positr...

Страница 3: ...ts 8 1 2 5 GAM LED Indicators 9 1 2 6 GAM Reset Button 11 Chapter 2 12 Step by Step Installation 12 2 1 Step by Step Installation Procedure 13 Chapter 3 19 WEB Management 19 3 1 Introduction 20 3 2 Sy...

Страница 4: ...THE GAM CIRCUITRY 8 FIGURE 5 GAM SERIAL MANAGEMENT PORT PINOUT 9 FIGURE 6 GAM GLOBAL STATUS LEDS 9 FIGURE 7 G HN PORTS LEDS 10 FIGURE 8 SFP LED 10 FIGURE 9 GAM RESET RST BUTTON 11 FIGURE 10 GAM LOGIN...

Страница 5: ...GAM Quick Installation Guide Positron Access Solutions 5 Document 180 0212 001 R02 Chapter 1 ______________________________________ About the GAM...

Страница 6: ...f DSL related technologies With G hn Operators deliver advanced services such as Gigabit High Speed Residential Internet and 4K IPTV without the high capital and operational expenses associated with a...

Страница 7: ...GAM SFP Connectors The GAM has one 1 SFP ports that support any MSA compliant SFP SFP modules Fiber 1G 10G and Copper RJ 45 100M 1G Important note When connecting the SFP port to a Passive Optical Ne...

Страница 8: ...ement ports located near the top right corner of the enclosure Figure 4 Local Management Ports are at the top right corner of the GAM circuitry The CRAFT port is a standard serial V 24 115200 8 N 1 po...

Страница 9: ...M uses three 3 LED indicators inserted in the cover of the IP67 enclosure to provide information about its global status and operating mode Figure 6 GAM global status LEDs LED Condition Function RPF O...

Страница 10: ...of the Reverse Power Feed source from a G1001 CR device at the customer end LED Condition Function G hn ports Off Blinking On Disabled or Link Down Bad or low speed G hn link Link is Up G hn port pow...

Страница 11: ...is Up Link Activity Table 3 SFP LED indicator 1 2 6 GAM Reset Button Press the RST button to reset the GAM When depressed for two 2 to ten 10 seconds it will perform a cold reboot of the GAM When depr...

Страница 12: ...GAM Quick Installation Guide Positron Access Solutions 12 Document 180 0212 001 R02 Chapter 2 ______________________________________ Step by Step Installation...

Страница 13: ...ecting the AC DC Power supply included as part of your GAM 4 CX You should skip this step if you are using a Reverse Power Fed GAM 4 CRX unless you plan to temporarily power the GAM for a temporary 12...

Страница 14: ...iver Step 3 insert the male power connector into the female receptacle You can now connect the other end of the 12Vdc 4A adapter to the local 110 220VAC power source The next step is the insertion of...

Страница 15: ...ugh length to reach the SFP cage while routing the fiber cable above the 2 x RJ 45 ports at the top right of the GAM enclosure Step 6 insert the fiber connectors into the SFP SFP module Note while an...

Страница 16: ...16 Document 180 0212 001 R02 You are now ready to install the ground wire into the ground lug at the bottom right edge of the GAM enclosure Step 8 insert the 6 AWG ground wire into the ground lug Ste...

Страница 17: ...left top left bottom right You can now connect the coaxial cable s to the F type COAX connectors of the unit Step 11 remove the protective cap on the F type connector s where you will attach a coaxial...

Страница 18: ...1 R02 Step 13 the top and bottom brackets are identical Using the Phillips screws supplied with the unit to fasten the bracket on the back side of the enclosure Step 14 Once both brackets are attached...

Страница 19: ...GAM Quick Installation Guide Positron Access Solutions 19 Document 180 0212 001 R02 Chapter 3 ______________________________________ WEB Management...

Страница 20: ...1 Logging into the WEB GUI The default configuration values of the GAM devices are IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Username admin Password Table 4 GAM default credentials Enter the s...

Страница 21: ...inistration Interface pre installed by Positron with one from your preferred Certificate Authority Note Secure HTTP is disabled by default HTTPS can be enabled via menu Configuration Security Switch H...

Страница 22: ...GAM Quick Installation Guide Positron Access Solutions 22 Document 180 0212 001 R02 Chapter 4 ______________________________________ Technical Specifications...

Страница 23: ...tification IEC 62368 1 Electromagnetic Compatibility EN 55032 FCC Part 15 Class A Other mark CE Operating Temperature 40 C to 65 C Storage Temperature 40 C to 70 C Operating Humidity Up to 95 relative...

Страница 24: ...P or G hn ports VLAN Supports up to 4K VLANs simultaneously out of 4096 VLAN IDs Port based VLAN IEEE 802 1Q tag based VLAN IEEE 802 1ad Q in Q double tag VLAN MAC based VLAN Management VLAN Private V...

Страница 25: ...s code point DSCP IP precedence TCP UDP source and destination ports 802 1p priority Ethernet type Internet Control Message Protocol ICMP packets IGMP packets TCP flag Quality of Service Hardware Prio...

Страница 26: ...MON Embedded RMON software agent supports RMON groups 1 2 3 9 history statistics alarms and events for enhanced traffic management monitoring and analysis IPv4 and IPv6 Dual Stack Coexistence of both...

Страница 27: ...GAM Quick Installation Guide Positron Access Solutions 27 Document 180 0212 001 R02 Chapter 4 ______________________________________ Safety and Warnings...

Страница 28: ...Only qualified personnel should service this system All wiring external to the product should follow the local wiring codes Use of this product in a manner other than defined in this installation gui...

Страница 29: ...iring Connection to these ports should be for temporary use during installation or maintenance THIS PRODUCT IS SUITABLE FOR MOUNTING ABOVE GROUND OR UNDER GROUND AT A MAXIMUM DEPTH OF 3 FEET THE UNIT...

Страница 30: ...GAM Quick Installation Guide Positron Access Solutions 30 Document 180 0212 001 R02 Chapter 5 ______________________________________ Warranty and Customer Service...

Страница 31: ...y information can be found in your Positron Access customer web portal http www positronaccess com Portal php Positron Access Solutions Sales Pricing Availability and Technical Support US and Canada 1...

Отзывы: