FS-GIGA Quick Installation Guide
Positron Access Solutions
22
Document 180-0147-001 R02
Observe local practice electrostatic discharge precautions when handling
electronic equipment. Do not hold electronic plugs by their edge. Do not touch
components or circuitry. Use a grounding wrist strap attached to a grounding
connection point. Use only ESD-protective packaging materials when
transporting equipment.
Care should be taken when installing in a closed or multi-unit rack environment to
ensure that the maximum operating ambient temperature of 65°C (149°F) is not
exceeded.
Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
Connect the unit only to a properly rated supply circuit. Reliable earthing
(grounding) of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to
the branch circuit (e.g. use of power strips).
During installation and service do not connect to a live power source. Ensure that
fuses are removed from the fuse panel.
This product is intended for installation in Restricted Access Locations only.
Mounting of equipment in a rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
The Positron Multi Pair span interface is designed to coordinate with a standard
350 Vdc (230 Vdc in Europe) gas discharge tube protector. Carbon block
protectors shall not be used.