background image

 

 

Part 11 

ROUTING THE CABLES 

Place all the cables required for connections to the main unit except 

those for  the integrated attachment  through the front part 
inside the stand assembly. Be sure not to damage any cable 

during this operation. The joint of the 
DB9 RS232 cable of the external 
devices and the RS232 conversion 
cable if used is most  recommended to 
be kept inside the base stand assembly. 

 
 
 

Now, turn the adjustable stand assembly back to normal orientation 

and arrange all cables to come out of the area for mounting main unit from the 
bottom edge for ease of later operation. 

PREPARING THE MAIN UNIT 

On the back of the main unit, there is a service window among the 4 

matching pegs. Remove the service window lock screw to find several jumpers. 
The jumpers in this window are designated for VGA port and COM port power 
supply function. Please consult your dealer for technical support on setup of 
these jumpers. Please note that only those qualified 
technicians may adjust in the service window with 
information from Posiflex and  the contents in the 
service window may change without notice as time 
develops. 

 

 
 

SIDE MOUNT UPGRADE KIT 

Remove the 2 circled screws in last picture above 

to remove the cover for side mount upgrade kit. Take out 
the cable inside this cover as circled in right picture and 
remove the 2 shorting jumpers inside and then connect it to 
connector inside the side mount upgrade kit like SD400 as 

arrowed in same picture. Gently arrange the excessive 
length of this cable back in the hole and  screw-fit  it  back to the position 
originally occupied by the cover. Please reserve the cover if there is chance to 
have the side mount kit removed in the future. 

DESKTOP MOUNTING

KS6115:258~355

 

Route Cables through Front Part 

Connect this End to Main Unit 

Service Window 
Lock Screw 

Jumpers 

Содержание KS - 6215N

Страница 1: ...esulting from the furnishing performance or use of this material This information is provided as is and Posiflex Technologies Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware con...

Страница 2: ...improper maintenance reduces the battery life dramatically Always fully recharge the battery at least once every 3 months if the battery is not connected Always disconnect the UPS battery from the system if the system is to be left OFF for more than 72 hours to prevent possible damage Only connect the UPS battery back right before you are going to re power on the system Replace the battery as soon...

Страница 3: ...NTRODUCTION PRODUCT PICTURES Front Views Side Views 1 1 11 12 Slim base Universal Base 10 10 9 9 6 5 Slim base 13 14 15 6 1 Slim base 6 3 4 1 1 Universal Base Slim base Universal Base 4 5 6 8 7 7 8 9 9 6 5 2 2 ...

Страница 4: ... Removal hollow in cable cover 9 Lock release lever for tilt angle adjust 10 Lock release button for main unit detach 11 Touch open cover 12 Power switch 13 Brightness adjust thumb wheel 14 Touch open door latch 15 PS 2 KB port 16 Rear connect cover 17 Power connector hole 18 Cable exit 19 2nd Cable exit 18 Universal Base 21 Slim base 18 19 20 21 1 1 Slim base Universal Base 7 7 6 5 18 18 16 16 17...

Страница 5: ...port WinCE Win XP Pro WEPOS POS Ready and Linux environment f High quality 15 TFT active matrix LCD panel g Brightness control by either software or hardware h Vertical type LCD panel with easy tilt angle adjustment from 15 to 70 i Durable resistive type leading edge Infra Red type optional touch panel that endures 35 million touches min at same spot j Spill proof water resistant structure allowin...

Страница 6: ...t MODEM ring or LAN Option Items Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR2 SDRAM memory expansion up to 1GB b RS232 interface Infra Red type touch panel durable for 50 million touches min at same spot c 2 HDD installation or uDOC d Integrated side mount upgrade kit SD400 MSR finge...

Страница 7: ...ible then Please first note orientations of every existing cable connection and then disconnect every cable properly before separating the main unit from the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port Please also note that the fixing screws have to be loosened free prior to disconnection such as th...

Страница 8: ...om plate up and the inside of an example slim base model looks like this in the above right picture The inside of an example universal base model will look like the picture on next page Both with numbered items listed on next page However there could be some variation to the contents inside depending on what option items actually installed Step A Prepare a soft clean flat surface such as a piece o...

Страница 9: ...through the 2 standing slits on base box to fix the battery in position firmly Route the battery connection cable through appropriate passage to the battery connector on the main unit Please remove the UPS battery bracket fixing screw and slide right the UPS battery bracket to take it out for universal base model as in left picture Put the battery in at the other end first and remount the bracket ...

Страница 10: ...or illustration purpose only Please push the plastic hook plate with finger through the top opening in the stand assembly to remove the rear connect cover 12 2nd LCD Panel Or Customer Display Fit the joint base of PD 2501 or PD 2602 or LM 6101 to the rear connect cover opening Please route the interface cable through the normal cable exit under the joint base as in the 2 pictures Fit 2 screws thro...

Страница 11: ...ort and COM port power supply function Please consult your dealer for technical support on setup of these jumpers Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops SIDE MOUNT UPGRADE KIT Remove the 2 circled screws in last picture above to remove the cov...

Страница 12: ...ed type touch panel is used KS 6115U 294 5 391 5 WALL MOUNTING The wall mount model is delivered without any base but with a wall mount kit Please follow the installation guide that comes with the wall mount bracket to fix the wall mount bracket on wall and then hang the main unit with the matching pegs into the matching holes on wall mount bracket Please note that since there is no base for the w...

Страница 13: ... care of software restoration after OS recovered A Posiflex supplied USB interface CDROM drive will be required for such action Other brand CDROM drive may require its specific driver different from what supported in the recovery CD Should there be any difficulty in using the Posiflex supplied USB interface CDROM drive in recovery please try disable the USB 2 0 function of system BIOS setup by goi...

Страница 14: ...Part 14 Inc shall not be responsible for any technical support to questions arisen due to non preloaded OS ...

Страница 15: ... hours every month for temperature over 30 C Temperature above 40 C must be strictly avoided as it could cause termination of battery life and unexpected result even if the battery is not in work The UPS battery can support basically the data preservation and smooth running of the system during intermittent or few minutes 15 30 min depending on loading and battery condition power failure Battery r...

Страница 16: ... power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation POWER ON OFF Touch Open Cover A gentle tap on the touch open cover at left side of the main unit will open the cover and show the power switch thumb wheel knob fo...

Страница 17: ...re registers may be confused causing trouble for system restart or even this forced power off please disconnect the UPS battery if installed and the AC power supply for few minutes This may allow all hardware registers to reset This switch can also be programmed as an ON only switch That means if the application program issues a command compliant with the KS series technical manual this switch wil...

Страница 18: ...et Please note that if the KS system is improperly turned off before a complete boot up procedure the above preset power on control functions will be disabled until next turning off after a complete boot up DISPLAY ISSUES Main LCD Display For best viewing result please set your display resolution at 1024 x 768 with 16 2 M colors In configuration of system memory max 64 MB can be shared as the vide...

Страница 19: ...rner of the main unit but no direct access port in the main unit The external access to audio ports can be found in the side mount option kit like SD 400 with a Microphone in and a stereo line out jacks at its bottom surface as circled in the right picture The internal speaker will be automatically disconnected when a plug is inserted in the line output jack HDD SATA PORTS The 2 5 HDD if installed...

Страница 20: ...f the mouse To obtain the effect like clicking on the right button of a mouse touching any point on the screen surface after touching the right click sticky button results as a click on the right button of the mouse at that point Posiflex USB Touch Manager A program named Posiflex USB Touch Manager and a right click sticky button tool in the program group Posiflex USB Touch Tools is installed in t...