Part 12
CONNECTING AC POWER
The power supply operating voltage
must
be checked to support the
city power supply specification and switch selected if necessary. This must be
done
WITHOUT
any connection to the AC power.
The operating voltage selection switch is located close to the power
input connector in the main connection area inside the back cable cover.
The switch should indicate either 115 volts or 230 volts. When set at
115 volts the acceptable power supply voltage range is 103 volts to 122 volts
whilst at 230 volts the acceptable power supply voltage ranges from 207 volts
to 244 volts.
The power supply cable should first be connected to the power inlet
(but
NOT
the wall socket). This cable should be consolidated with other cables
and come out of the connection area through the bottom opening of the chassis.
OPERATING SYSTEM RECOVERY
For FT systems with operating system in the Compact Flash Card,
once the Compact Flash is damaged for any reason, the thin client may fail to
boot.
A bootable new Compact Flash Card will be required to have the
workstation back to work
. Please follow instructions given by the System
Integrator to deal with situations like that. One more advice for CF Card
application is that in spite of the fact that it is used in the way like an ordinary
HDD, usual utilities such as
FDISK.EXE or FORMAT.COM shall never be
used on CF Card
otherwise the boot sector of operating system itself may be
damaged and causing the CF Card no longer bootable.
For FT systems preloaded with Windows XP Pro or WEPOS on HDD,
Posiflex provides recovery CD delivered with the touch terminal for the
preloaded operating system. The System Integrator shall take care of software
restoration after OS recovered. A Posiflex supplied USB interface CDROM
drive will be required for such action. Other brand CDROM drive may require
its specific driver different from what supported in the recovery CD.
Please use the recovery CD in rescue operation only. Using it
otherwise may wipe out whatever stored in the HDD!
All upgrade devices
drivers needed for manual installation in usual way are available in the
subfolder “\drivers” in OS recovered HDD and the latest versions of these
required drivers will be available on our web: http://www.posiflex.com.tw.
Then follow instructions from your system integrator for software recovery.
OPERATING SYSTEM INSTALLATION
This product is a highly professionalized equipment. The installation
of an OS into a machine without any preloaded OS could constitute major
difficulty for average user or obstacle by possibly unintentional negligence
even for PC veterans to accomplish such a task. Therefore, OS installation into