Posh POS 708 Скачать руководство пользователя страница 4

POS 708 USER MANUAL Ver. 1.6 

 

 

 

 

Figure 5: Dip Switch On/Off Position and numbering

 

 

Sw1 (ON):  Alarm ON will stay on for only 60 seconds if any Drawers are left open for more then XX 
Seconds 

Sw1 (OFF): Alarm ON will Stays on until all Drawers are closed  

Sw2  Sw 3:  Wait Time when any drawer is open before sounding Alarm. See Table 1 

Sw4 (ON): Alarm Speaker Eenabled  

Sw4 (OFF): Alarm Speaker Disabled  

 

Alarm Option A Sw1 (ON): Alarm will sound when drawer is open for XX seconds then turn off Alarm after 60 
seconds or close all drawers.  

Alarm Option B Sw1 (OFF): Alarm will sound when drawer is open for XX seconds. Close drawer to turn off 
Alarm.  

 

 

Table 1: POS708 Dip Switch 2-3 

 

POS 708-RS232 Communication setting:  9600 Baud, 8 Data Bits, No Parity, 1 Stop bit 

 

Содержание POS 708

Страница 1: ...POS 708 USER MANUAL Ver 1 6 1 POS 708 Dual Cash Drawer Alarm USB RS232 ...

Страница 2: ...ired to support a drawer open switch The drawer open switch should be N O Normally Open when the cash drawer is closed The POS708 can only support N O cash drawers DO NOT MIX Drawer Switch types You can use up to TWO N O drawer s on the POS708 See Figure 5 6 for typical cash drawer wiring requirements The cash drawer alarm features of the POS708 do not need any software changes to your application...

Страница 3: ...d other service industries NO software changes are needed with the POS708 and Psen combination If you are using a POS708 with Ver 1 1 or Ver 1 3 PCB you will require a special 708 PSen designed for these PCB Features of the POS708 include a dual RJ12 female connector status LED 24 Vdc external power supply Included with POS708 and an alarm that is switch selectable The POS 708 has no internal jump...

Страница 4: ...hen any drawer is open before sounding Alarm See Table 1 Sw4 ON Alarm Speaker Eenabled Sw4 OFF Alarm Speaker Disabled Alarm Option A Sw1 ON Alarm will sound when drawer is open for XX seconds then turn off Alarm after 60 seconds or close all drawers Alarm Option B Sw1 OFF Alarm will sound when drawer is open for XX seconds Close drawer to turn off Alarm Table 1 POS708 Dip Switch 2 3 POS 708 RS232 ...

Страница 5: ...re 7 Typical Star Cash Drawer Wiring Pin Number Drawer 1 Signal Name Drawer 2 Signal Name Direction 1 Frame Ground Frame Ground Ground 2 Drawer 1 Sink Signal Drawer 2 Sink Signal Input 3 24 VDC 24 VDC Power 4 24 VDC 24 VDC Power 5 Drawer 2 Sink Signal Drawer 1 Sink Signal Input ...

Страница 6: ...daptor supplied also provides the 5V power on the RS232 version only A flashing LED indicates that an event is active Drawer is Open or in a Timing Loop INSTALLATION Select Cash Drawer Aalarm On state using Dip switches 1 60 seconds or Stay on until all drawers are closed Select Time duration for the Selected Option Dip switches 2 3 Wait time when any drawer is open before sounding Alarm Connect C...

Страница 7: ...er Connectors 2 x RJ12 Drawer 1 Drawer 2 Dimensions 80 x 45 x 28 5 mm WxDxH 150 gm USB RS232 Cable Lengths 180 cm 6 Feet Max distance can be up to 15 Feet for USB only RS232 DB9F cable is 6 Feet max 100 FT cable for RS232 Humidity Temp 10 90 relative humidity 20C to 55C Drawers Supported Star Epson Citizen IBM and compatible cash drawers with RJ12 connection N O Normally Open Drawer Switch only Pi...

Страница 8: ...akes no claims or warranties with respect to the content or accuracy of this publication or the product it describes including warranties of fitness or merchantability for a particular purpose The Manufacturer shall not be liable for any special incidental or consequential damages nor damages due to use or misuse born from integration into any mechanical electrical or computer system The Manufactu...

Отзывы: