Posh POS 708 Скачать руководство пользователя страница 2

POS 708 USER MANUAL Ver. 1.6 

 

POS708 Cash Drawer Alarm option 

     

The POS708 provides retailers peace of mind with their employees.  Through selectable options, the POS708 
can notify employees with an electronic buzzer if a cash drawer is left open for more then a selectable amount of 
time (15 - 40 seconds). The electronic buzzer can be selected to stay on for 60 second or stay on until all the 
drawers are closed.  
 
Most IBM, Star, Epson, Citizen and other compatible Cash Drawers are supported two. The unique design of the 
POS708 provides the retailer the option of connecting two cash drawers to one USB / RS232 port without the 
use of special cables.  
 
The POS708 also uses the same RJ12 cash drawer port off the POS printers and a 24 Vdc Adaptor is used for its 
power ( 24Vdc Adaptor is included with the POS 708) . See Figure 1 for the Connection illustration. Note that 
the push button on the POS708 has no effect on any Cash Drawer Alarm options. By pressing the top Push 
button, you will hear a short beep and the LED will flash. The push button on top is used for testing purposes 
only.  
 
In order for the cash drawer alarm to work, the cash drawer must be wired to support a drawer open switch. The 
drawer open switch should be N/O (Normally Open when the cash drawer is closed). The POS708 can only 
support N/O  cash drawers. DO NOT MIX Drawer Switch types. You can use up to TWO N/O drawer(s) on the 
POS708.  See Figure 5& 6 for typical cash drawer wiring requirements.  
 
The cash drawer alarm features of the POS708 do not need any software changes to your applications. The cash 
drawer alarm works independent of the OS system and all its applications. The POS708 monitors the cash 
drawer open switch to trigger the alarm. See Figure 1 for typical connection for multiple cash drawers. 
 

POS708 Paper Sensor Alarm option 
 

The Paper Sensor Option operates the same as a cash drawer switch. When paper is present the paper sensor will 
trigger the alarm as per its dip switch settings. The Paper Sensor Alarm features of the POS708 do not need any 
software changes to your application. The Paper Sensor alarm works independent of the OS  and all applications. 
Use the same setting as the cash drawer alarm when using a Paper Sensor POS-Psen. Note that you can only use 
up to TWO POS-Psen with one the POS708. See Figure 2 to typical Psen connection. 

 

 

                    

 

 
 

Figure 1:POS708 Cash Drawer Alarm connection illustration for multiple (N/O) Normally Open cash drawers 

to Computer. You Can also Mix Cash Drawers and PSen on the Same POS708 

 
 
 

Содержание POS 708

Страница 1: ...POS 708 USER MANUAL Ver 1 6 1 POS 708 Dual Cash Drawer Alarm USB RS232 ...

Страница 2: ...ired to support a drawer open switch The drawer open switch should be N O Normally Open when the cash drawer is closed The POS708 can only support N O cash drawers DO NOT MIX Drawer Switch types You can use up to TWO N O drawer s on the POS708 See Figure 5 6 for typical cash drawer wiring requirements The cash drawer alarm features of the POS708 do not need any software changes to your application...

Страница 3: ...d other service industries NO software changes are needed with the POS708 and Psen combination If you are using a POS708 with Ver 1 1 or Ver 1 3 PCB you will require a special 708 PSen designed for these PCB Features of the POS708 include a dual RJ12 female connector status LED 24 Vdc external power supply Included with POS708 and an alarm that is switch selectable The POS 708 has no internal jump...

Страница 4: ...hen any drawer is open before sounding Alarm See Table 1 Sw4 ON Alarm Speaker Eenabled Sw4 OFF Alarm Speaker Disabled Alarm Option A Sw1 ON Alarm will sound when drawer is open for XX seconds then turn off Alarm after 60 seconds or close all drawers Alarm Option B Sw1 OFF Alarm will sound when drawer is open for XX seconds Close drawer to turn off Alarm Table 1 POS708 Dip Switch 2 3 POS 708 RS232 ...

Страница 5: ...re 7 Typical Star Cash Drawer Wiring Pin Number Drawer 1 Signal Name Drawer 2 Signal Name Direction 1 Frame Ground Frame Ground Ground 2 Drawer 1 Sink Signal Drawer 2 Sink Signal Input 3 24 VDC 24 VDC Power 4 24 VDC 24 VDC Power 5 Drawer 2 Sink Signal Drawer 1 Sink Signal Input ...

Страница 6: ...daptor supplied also provides the 5V power on the RS232 version only A flashing LED indicates that an event is active Drawer is Open or in a Timing Loop INSTALLATION Select Cash Drawer Aalarm On state using Dip switches 1 60 seconds or Stay on until all drawers are closed Select Time duration for the Selected Option Dip switches 2 3 Wait time when any drawer is open before sounding Alarm Connect C...

Страница 7: ...er Connectors 2 x RJ12 Drawer 1 Drawer 2 Dimensions 80 x 45 x 28 5 mm WxDxH 150 gm USB RS232 Cable Lengths 180 cm 6 Feet Max distance can be up to 15 Feet for USB only RS232 DB9F cable is 6 Feet max 100 FT cable for RS232 Humidity Temp 10 90 relative humidity 20C to 55C Drawers Supported Star Epson Citizen IBM and compatible cash drawers with RJ12 connection N O Normally Open Drawer Switch only Pi...

Страница 8: ...akes no claims or warranties with respect to the content or accuracy of this publication or the product it describes including warranties of fitness or merchantability for a particular purpose The Manufacturer shall not be liable for any special incidental or consequential damages nor damages due to use or misuse born from integration into any mechanical electrical or computer system The Manufactu...