XSTREAM
USER MANUAL
ACCESSORIES
OXYGEN ALERT!
All accessories which may be ”wetted” by gas containing >21% oxygen
must be approved and maintained for oxygen use.
WARNING:
Notice that EN 250 marked equipment must only be used with
air according to EN 12021. Violation can cause a fire and/or the
equipment may not function properly.
WARNING:
The use of accessories which have not been recommended, can
seriously impair the function of your equipment.
Pressure-gauge hoses without a restriction in the connection can,
if the hose is punctured, allow a powerful jet of gas to escape.
Xstream can be combined with the following equipment/accessories, given that
the manufacturers’ instructions foruse are strictly adhered to:
- Xstream EN 144-3 rebuild kit
- Xstream hoses
- Xstream (neck strap) surgical cord
- Poseidon Jetstream 2nd stage and hose, EN 250
- Poseidon Jetstream 1st stage, EN 250
- All CE marked or EN 250 designated cylinder valves
- Yoke clamp
- All CE marked approved pressure-gauge hoses rated for WP 300 bar using
UNF 7/16” connection.
- All CE marked pressure gauges, diving computers, and HP transmitters/
senders rated for WP 300 bar (4351 psi)
- All CE marked IP-hoses for BCD’s and dry-suits. Xstream feeds 7.5-9.5 bar
(109-138 psi) to BCD or dry-suit.
- All CE and EN 250 marked mouthpieces.
21