background image

XSTREAM

USER MANUAL

General safety regulations

Although the regulator is functional with pure oxygen and has excellent breathing

characteristics down to 200m (656 ft), the usage is restricted by human 

limitations, or, by limitations set out by the dive training organisation, whichever 

is lower.

Poseidon only warrants the regulator performance as specified herein, and 

cannot be held responsible for improper preparations, incorrect gas mixing and 

planning, or diving beyond individual medical, psychological and physical 

limitations.

Limitations of use: 

Xstream Deco, Oxygen and Duration models no higher oxygen content than 

99,95% by volume.

Xstream Deep models manufactured after 2015 are Nitrox Ready with a maximum 

oxygen content of EAN 40, and a maximum Helium content of 94% Xstream Dive 

and octopus only for use with air and a maximum depth of 50 meters.

Maximum depth never more than 200 meters (656 ft), but normally limited by 

medical effects of the gas.

The oxygen partial pressure must normally not exceed 1.4 bar (20.3 psi), under 

the foreseeable maximum diving depth. Only if established oxygen exposure 

tables are strictly adhered to, and a responsible organisation is planning dives with 

increased exposures, elevated levels can be accepted for a shorter period of time.

The oxygen partial pressure must never be lower than 0.2 bar (2.9 psi), under the 

foreseeable minimum diving depth.

The nitrogen partial pressure must not exceed 3.2 bar (46.4 psi), under the 

foreseeable maximum diving depth. Inhaling cold gas and exhaling warmed gas, 

represents energy losses of the human body (thermal imbalance, hypothermia).

This effect increases with increasing depth and can result in a sudden 

unconsciousness. Diving to extreme depths this effect must be considered, 

calculated and planned for and preventive actions must be taken, such as proper 
thermal protection and pre-heated gas.

Xstream is for unlimited use in water temperatures from water freezing 

temperature tice +1°C to +50°C (122°F). The freezing temperature depends on 

salt content. Diving with gas blends other than air, or deeper than 18 m (59 ft), or 

8

Содержание Xstream Deco

Страница 1: ...XSTREAM USER MANUAL 1 0 T M...

Страница 2: ......

Страница 3: ...ge 10 Xstream 1 st Stage 11 Poseidon T D A 12 Deep Deep90 1 st Stage Trimix Air Nitrox Ready 12 Deco Oxygen 1 st Stage Oxygen Ean Air 13 Duration Duration En 144 3 1 st Stage Ean Air 14 Dive90 1 St St...

Страница 4: ...2...

Страница 5: ...risymbols as follows DANGER Alert boxes that are RED contain extremely critical information related to the safety and well being of the diver Failure to comply with information contained in these boxe...

Страница 6: ...ems AB Text photographs and figures copyright 2019 by Poseidon Diving Systems AB ALL RIGHTS RESERVED Manual Version 1 0 February 2019 DANGER Do not attempt to use the Poseidon Xstream without proper t...

Страница 7: ...l and at the same time feel the weightlessness when meter by meter you descent into a world of your own Nothing shall disturb your concentration No wheels or knobs that need adjusting No regulators th...

Страница 8: ...EN 738 1 for oxygen pressure shocks Type approvement certificate no 020341 020342 and 020343 is issued by SGS United Kingdom Ltd Ellesmere Port CH65 3EN United Kingdom Notified body number 0120 Produ...

Страница 9: ...ure containing greater than 21 oxygen up to 40 Enriched Air Nitrox IP Interstage pressure the pressure existing between the 1st stage and the 2nd stage valve HP High pressure the pressure inside the S...

Страница 10: ...e gas The oxygen partial pressure must normally not exceed 1 4 bar 20 3 psi under the foreseeable maximum diving depth Only if established oxygen exposure tables are strictly adhered to and a responsi...

Страница 11: ...suit inflation Helium has very low insulating proerties and contributes to a more rapid cooling of the body Preferably Argon shall be used but must never be inhaled Insulating or actively heating of...

Страница 12: ...he operation the regulator will continue to function but must only be used for immediate ascent Integrated surgical hose fixing points safely secures the regulator to the diver but in an emergency all...

Страница 13: ...he first stage is a balanced rolling diaphragm ball valve producing extreme leak tightness Conventional designs are sensitive to wear misalignment and manufacturing precision A ball always finds its c...

Страница 14: ...gm It is constructed without compromise to any detail to prevent cold reaching the sensitive area Using Poseidon T D A a regulator can free flow air in fresh water of 0 C 32 F for at least 10 minutes...

Страница 15: ...ast two numbers in the manufacturing year This regulator was manufactured in 2014 We changed from 6 digit serial numbers to 7 digit serial numbers in 2010 DECO OXYGEN 1 ST STAGE OXYGEN EAN AIR O4 stan...

Страница 16: ...mg m2 hydrocarbons The Xstream Oxygen 1st stage is only used on the Mk VI and SE7EN Rebreathers DURATION DURATION EN 144 3 1 ST STAGE EAN AIR Xstream Duration shares the performance and specification...

Страница 17: ...e gas by as muchas12 C 22 F undercertainconditions Using a long hose requires some basic knowledge in its use and routing to take the full advantages Poseidon does not recommend the use of hose protec...

Страница 18: ...XYGEN ALERT If you have an Oxygen Deco or Duration model be absolutely sure not to touch the o ring or other inner connection areas with your fingers since grease from your fingers are a combustible c...

Страница 19: ...rials 3 Remove the protective cap on the first stage Check that the O ring on the regulator s connection is intact and clean then mount the regulator on the cylinder valve Turn the handwheel yoke knob...

Страница 20: ...as to blow out possible debris 6 Check the pressure gauge to see that the tank is full whilst purging by watching the almost zero deflection of the needle this indicates that the air is flowing corre...

Страница 21: ...gasses can be present WARNING If on any occasion the safety valve starts bleeding there is a 1st stage failure Due to the construction you can still breathe normally from the regulator To avoid exces...

Страница 22: ...ever subjected to mechanical shocks or impacts OXYGEN ALERT Never unscrew a pressurised regulator from the tank This can create a jet of gas over the o ring and cause a fire WARNING Never use the 1st...

Страница 23: ...ow a powerful jet of gas to escape Xstream can be combined with the following equipment accessories given that the manufacturers instructions foruse are strictly adhered to Xstream EN 144 3 rebuild ki...

Страница 24: ...s mix Always follow established calculation methods and mixing procedures for mixing a breathable gas These are not described herein WARNING Xstream Deco Xstream Oxygen and Xstream Duration must not b...

Страница 25: ...the connection can if the hose is punctured allow a powerful jet of air to escape Self made and or by Poseidon unauthorized changes modifications to the product may lead to reduced functionality and...

Страница 26: ...ppm CO2 500 ppm Water dew point 45 C 50 F Lubricants droplets mist 0 5mg m3 Water 25 mg m3 Gaseous hydrocarbons 15 ppm Condensed hydrocarbons 0 1 mg m3 Solid particles 2 microns Approved gas mixes for...

Страница 27: ...Air EAN 50 Oxygen Deco Air Oxygen Maximum working pressure 300 bar 4351 psi Cold water performance Exceeding EN 250 requirements for cold water use Approvals Type Approved acc to EU Directive Personal...

Страница 28: ...Upstream servo valve Safety valve opening pres 18 1 bar 261 14 psi Swivelling Around axis can be used either side Material ASA Brass TPU Silicone PU Venturi assist Automatic Inhalation control Automat...

Страница 29: ...NF 3 8 1 HP UNF 7 16 Deep 90 Dur 90 Oxygen 5 IP UNF 3 8 2 HP UNF 7 16 Connection Only Duration90 manuf in 2004 or later Deep Dive Dive90 Duration Duration90 Duration EN 144 3 Deco Material Brass plast...

Страница 30: ...XSTREAM USER MANUAL 28...

Страница 31: ...mportant to understand that this equation does not apply to any other regulator since the coefficients and characteristics are strongly dependent on the regulator construction Full regulator capacity...

Страница 32: ...oo low the valve is slightly opened Have the regu lator correctly set by an authorised dealer The bubbles remain cracking pressure is correct The servo valve is severely jammed by salt crystals Have t...

Страница 33: ...he sound is occurring even while diving Incorrect lubri cants have been used Have the regu lator correctly lubricated by an authorised dealer Gas vents from 2nd stage on opening the cylinder valve Doe...

Страница 34: ...room environment made up by materials chosen to expose lowest possible risk x failure effect product and are tested and approved for oxygen use It is strictly prohibited to use the Poseidon Xstream Ox...

Страница 35: ...as a minimum but preferbly once every 12 months or as often as it is estimated to be necessary You can do some fault correcting servicing and or preventive servicing yourself Following the instructio...

Страница 36: ...Poseidon Diving Systems AB keredsv gen 1 SE 421 63 V stra Fr lunda Sweden Phone 46 31 734 29 00 E mail info poseidon com www poseidon com...

Отзывы: