Radiation Safety
•
This x-ray device may be dangerous to operator, patient and bystander unless safe
exposure factors, operating instructions and maintenance schedules are observed.
• Do not operate if the backscatter shield or collimator cone are broken!
1) Ensure proper registration and compliance with any such regulation.
2)
In implementing a radiation protection program, please consult any state, provincial, and local regulations
governing radiation protection and the use of x-ray equipment.
3) Operator must follow all applicable regulatory guidelines and in-house radiation protection program in
regard to patients and operators who are pregnant or expect to become pregnant.
4) Operators must be fully acquainted with industry safety recommendations and established maximum
permissible doses.
5) Optimal operator radiation backscatter protection exists when:
-
the backscatter shield is positioned at the outer end of the collimator cone,
- the backscatter shield is parallel to the operator,
-
the backscatter shield is close to the patient,
-
the patient tilts their head when needed to accommodate exposures, and
-
the operator remains within the Significant Zone of Occupancy immediately behind the device shield.
6)
Do not enable
Rextar X
until patient and operator are positioned and ready for the exposure,
reducing the likelihood of interruption and preventing inadvertent exposure of anyone to x-rays.
7)
Do not attempt an exposure if anyone else is positioned immediately behind the patient (in line with the
direction of x-ray emission).
If others are assisting, then they should wear protective covering.
Incorrect placement
Correct placement
P.37B
Содержание REXTAR X
Страница 2: ...This page intentionally left blank...
Страница 4: ......
Страница 6: ...This page intentionally left blank...
Страница 30: ...POSDION Co Ltd Page 24 Rev 02 PN 100304 00 REXTAR X Manual 3 Tank Label Pic1 7 2 3 TANK Label bottom...
Страница 52: ...POSDION Co Ltd Page 40 Rev 02 PN 100304 00 REXTAR X Manual 3 Block diagram...
Страница 55: ...POSDION Co Ltd REXTAR X Manual PN 100304 00 Rev 02 Page 43 For Authorized Service and Test Technicians...
Страница 56: ...POSDION Co Ltd Page 44 Rev 02 PN 100304 00 REXTAR X Manual For Authorized Service and Test Technicians...
Страница 57: ...POSDION Co Ltd REXTAR X Manual PN 100304 00 Rev 02 Page 45 For Authorized Service and Test Technicians...
Страница 58: ...POSDION Co Ltd Page 46 Rev 02 PN 100304 00 REXTAR X Manual For Authorized Service and Test Technicians...
Страница 59: ...POSDION Co Ltd REXTAR X Manual PN 100304 00 Rev 02 Page 47 For Authorized Service and Test Technicians...
Страница 60: ...POSDION Co Ltd Page 48 Rev 02 PN 100304 00 REXTAR X Manual For Authorized Service and Test Technicians...
Страница 61: ...POSDION Co Ltd REXTAR X Manual PN 100304 00 Rev 02 Page 49 For Authorized Service and Test Technicians...
Страница 62: ...POSDION Co Ltd Page 50 Rev 02 PN 100304 00 REXTAR X Manual For Authorized Service and Test Technicians...
Страница 63: ...POSDION Co Ltd REXTAR X Manual PN 100304 00 Rev 02 Page 51 This page intentionally left blank...