background image

5

TROUBLESHOOTING GUIDE

The following information is intended as an aid in determining if problem exists. Pump and ram should be repaired only by 

authorized Porto-Power Service Center. For repair service, contact service center in your area.

Symptom

Possible Causes

Corrective Action

Erratic action

 • 

Air in system or pump cavitation.

 • External leakage in ram.

 • Ram sticking or binding.

 • Vent the system (refer to figure 2).

 • Contact service center.

 • Contact service center.

Ramr will not extend, or 

respond to pressurized fluid

 • 

Overload condition.

 • Loose/Faulty couplers.

 • Oil level in pump is low.

 • Remedy overload condition.

 • Tighten/Replace couplers.

 • Fill and bleed the system.

Ram extend only partially

 • Oil level in pump is low.

 • 

Overload condition.

 • Ram is sticking or binding.

•  Pump malfunction.

 • Fill and bleed the system.

 • Remedy overload condition.

 • Contact service center.

 • Contact service center.

Ram move slower than normal

 • Loose connection or coupler.

 • Restricted hydraulic line or fitting.

 • Pump not working correctly.

 • Ram seals leaking.

 • Tighten connection or coupler.

 • Clean and replace if damaged. 

 • Check pump’s operating instructions.

 • Contact service center.

Ram responds to pressurized fluid, but 

system does not maintain pressure

 • Overload condition.

 • Pump malfunctioning.

 • Ram seals leaking.

 • Remedy overload condition.

 • Contact service center.

 • Contact

 

service center.

Oil leaking from ram 

 • Worn or damaged seals.

• Contact service center.

Ram will not retract or retracts slower 

than normal

  • Malfunctioning coupler, damaged 

application.

 • Pump reservoir overfilled.

 • Ram damage internally.

 •

 Secure load by other means

Depressurize

 pump and hoses, 

remove application and replace 

coupler.

 •

 Secure load by other means

Depressurize

 pump and hoses, 

remove application, then drain fluid to 

proper level.

 • Contact service center.

Poor performance

 • Oil level in pump is low.

 • Air trapped in system.

 • Ensure proper oil level.

 • Vent the system (refer to figure 3).

Содержание B65123

Страница 1: ...utomotive is a licensed trademark Operating Instructions Parts Manual Model Numbers B65123 B65145 SFA Companies 10939 N Pomona Ave Kansas City MO 64153 sales blackhawk automotive com This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Hydraulic Spreader ...

Страница 2: ...at decision Immediately after lifting loads must be supported by appropriate mechanical means PRODUCT DESCRIPTION NEVER rely upon a hydraulic spreader as a support device Immediately after lifting loads must be supported by appropriate mechanical means Always check connections before using Alteration of these products is strictly prohibited Use only those adapters and attachments provided and appr...

Страница 3: ...e is blocked or reduced Periodically inspect the hose for wear Do not pull position or move ram setup by the hose Use carrying handle or other means of safe transport Do not handle pressurized hoses Never attempt to grasp a leaking pressurized hose Ensure to release the system pressure before disconnecting hydraulic hose or connections Hydraulic fluid can ignite and burn Keep hydraulic equipment a...

Страница 4: ... wrench without first wrapping the jaws of such tool with rags or similar padding How to bleed air from system 1 Place pump at a higher elevation than the hose and ram as shown in figure 3 below 2 Operate pump to fully extend and retract the ram 2 or 3 times The objective is to force the air bubbles up hill and back to the pump reservoir 3 To bleed the air from pump reservoir simply open the oil f...

Страница 5: ...ter Contact service center Ram move slower than normal Loose connection or coupler Restricted hydraulic line or fitting Pump not working correctly Ram seals leaking Tighten connection or coupler Clean and replace if damaged Check pump s operating instructions Contact service center Ram responds to pressurized fluid but system does not maintain pressure Overload condition Pump malfunctioning Ram se...

Страница 6: ...r Description Qty 1 Spreader Base N A 1 2 Spreader Jaw Upper N A 1 3 C Clip 5304 00013 000 2 4 Pin F040 42004 000 1 5 Torsion Spring F040 42005 000 1 6 Piston N A 1 7 Back Up Ring 5904 00257 001 1 8 U Cup 5902 00330 000 1 9 Washer 5904 00250 002 1 10 Top Nut N A 1 11 Female Coupler B69477 1 Replacement Parts List Illustration for Model B65123 ...

Страница 7: ...A 1 2 Spreader Base N A 1 3 Return spring 521 2 0060 109 1 4 Return spring 521 2 0090 108 1 5 Spring pin 601 4 0030 059 2 6 Piston rod N A 1 7 O ring 1 8 Unloading pin H51 6 1202 104 1 9 O ring 1 10 Back up Ring 1 11 Retaining ring H51 6 1004 100 1 12 Pin H51 6 1003 108 1 13 Coupler B69477 1 Repair kit H51 3 9900 100 1 1 11 5 10 5 Replacement Parts List Illustration for Model B65145 ...

Страница 8: ...OSS WHATSOEVER 3 ANY IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO ONE YEAR OTHERWISE THE REPAIR REPLACEMENT OR REFUND AS PROVIDED UNDER THIS EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED 4 ANY MODIFICATION ALTERA...