6
ASSEMBLY INSTRUCTIONS
5a.
Hardware Used
E3 Wire Connector x 3
Adjust screws (D) to proper length by
screwing them completely into mounting strap
(B). Temporarily place fixture (A) over
mounting strap (B) to determine amount of
adjustment necessary for screws (D); screws
(D) should come through holes in fixture (A)
just enough so decorative nuts (C) will fit flush
against fixture (A) when mounted.
Once screws (D) are adjusted, use pliers (not
included) to tighten nuts (E) on screws (D)
until nuts (E) touch mounting strap (B).
4.
Unwrap BARE wire from BLACK and WHITE wires
on back of fixture (A). Prepare wire by stripping 3/4
inch of insulation from wire ends using wire
strippers (not included).
Connect WHITE wire from fixture (A) to WHITE
wire from outlet box using existing wire connector
or wire connector (AA). Connect BLACK wire from
fixture (A) to BLACK wire from outlet box using
existing wire connector or wire connector (AA).
Connect BARE/GREEN ground wire from outlet
box to BARE ground wire from fixture (A) using
wire connector (AA).
NOTE:
Screw wire connectors (AA) on in a
clockwise direction.
WARNING:
Never connect ground wire to
white or black power supply wires.
WARNING:
To reduce the risk of fire,
electrical shock or personal injury, wire connectors
(AA) provided with this light fixture are designed to
accept only one 12-gauge house wire and two
lead wires from the light fixture. If your house wire
is larger than 12-gauge or there is more than one
house wire to connect to the corresponding fixture
lead wires, consult an electrician for the proper
size wire connectors to use.
4
4
5a
5b
4
Outlet Box
Outlet Box
WHITE
WHITE
BLACK
BARE/GREEN
BLACK
B
A
C
D
E
AA
AA
AA
AA
Lowes.com/portfolio
5b.