![Porter 91101-100 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/porter/91101-100/91101-100_installation-operation-and-maintenance-manual_1580727021.webp)
Page 17
PLC LIGHT REFERENCE LEGEND (Top Row)
11. OPERATIONAL CHECK PROCEDURE - TROUBLESHOOTING GUIDE
To ensure the unit has been wired properly, the following provides an easily identifiable
cross check of the
Mat Mover
®
functions with a corresponding control panel light.
The following instructions are intended for a minimum of two people. One person must
observe the control panel lights, while the second person operates the unit. For proper
troubleshooting, the unit must be operated from the keyswitch location. In addition,
individual components (limit switches) must be actuated.
10.6
Disconnect power at power source and at control panel. To correct phasing,
switch wires L1 and L2 at control panel or junction box. After switching wires, turn
power “ON” at both the power source and control panel, and repeat Step 10.5.
10.7
If the installer is not on site at this time, switch the circuit breakers off, and
leave the keys with the appropriate personnel, informing same the unit cannot be
operated until the limit switches are set. Mark the unit “
Do Not Use
.”
Refer to Top Row of Lights
(Function Lights)
Programmable Logic Controller Illustration
Light Function
0 Keyswitch
“Down”
1 Keyswitch
“Up”
2
Left Hoist “Up” Limit Switch
3
Left Hoist “Down” Limit Switch
4
Left Hoist Reed Device Switch
5
Right Hoist “Up” Limit Switch
6
Right Hoist “Down” Limit Switch
7
Right Hoist Reed Device Switch
8 N/A
FUNCTION LIGHT LEGEND
9 N/A