background image

13

LUBRICATION

This tool has been lubricated with a sufficient amount of high grade lubricant
for the life of the unit under normal operating conditions. No further
lubrication is necessary.

BRUSH INSPECTION AND LUBRICATION

For your continued safety and electrical protection, brush inspection and
replacement on this tool should ONLY be performed by an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA
FACTORY SERVICE CENTER.

At approximately 100 hours of use, take or send your tool to your nearest
authorized Porter-Cable Service Station to be thoroughly cleaned and
inspected. Have worn parts replaced and lubricate with fresh lubricant. Have
new brushes installed, and test the tool for performance.

Any loss of power before the above maintenance check may indicate the
need for immediate servicing of your tool. DO NOT CONTINUE TO
OPERATE TOOL UNDER THIS CONDITION. If proper operating voltage is
present, return your tool to the service station for immediate service.

SERVICE AND REPAIRS

All quality tools will eventually require servicing or replacement of parts due
to wear from normal use. These operations, including brush inspection and
replacement, should ONLY be performed by either an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA
FACTORY SERVICE CENTER. All repairs made by these agencies are fully
guaranteed against defective material and workmanship. We cannot
guarantee repairs made or attempted by anyone other than these agencies.

Should you have any questions about your tool, feel free to write us at any
time. In any communications, please give all information shown on the
nameplate of your tool (model number, type, serial number, etc.). 

ACCESSORIES

A complete line of accessories is available from your Porter-Cable 

Delta Supplier, Porter-Cable 

Delta Factory Service Centers, and

Porter-Cable Authorized Service Stations. Please visit our Web Site

www.porter-cable.com

for a catalog or for the name of your nearest

supplier.

WARNING:

Since accessories other than those offered by 

Porter-Cable

Delta have not been tested with this product, use of such accessories 

could be hazardous. For safest operation, only 

Porter-Cable 

Delta 

recommended accessories should be used with this product.

901452 - 03-28-02.qxd  5/15/02  9:07 AM  Page 13

Содержание TIGERCLAW 740

Страница 1: ..._______________ Type ___________________________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully...

Страница 2: ...l ELECTRICAL SAFETY 1 Double insulated tools are equipped with a polarized plug one blade is wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully i...

Страница 3: ...n it ON or OFF A tool that cannot be controlled with the switch is dangerous and must be repaired 4 Disconnect the plug from the power source before making any adjustments changing accessories or stor...

Страница 4: ...reakage potential when making angle and scroll cuts 8 Use only recommended blades with this tool Do NOT use jig saw blades without the proper blade adaptor 9 To prevent accidental electrical shock the...

Страница 5: ...esigned for A C current only Refer to the specification plate on your tool for proper voltage and current rating CAUTION Do not operate your tool on a current on which the voltage is not within correc...

Страница 6: ...the blade release collar A Fig 2 counterclockwise as viewed from the front of the saw NOTE The Quik Change pivoting guide shoe can be temporarily removed to make blade installation easier Release lock...

Страница 7: ...her blade as a tool to aid in removing the broken piece see Fig 5 While holding the release collar in the open position use the tip of another blade to hook the broken piece and pull it from the clamp...

Страница 8: ...e front scroll housing To reinstall slide the guide shoe into the front scroll housing and close the lock lever as shown in B Fig 4 The shoe extension can be adjusted and locked in any one of three di...

Страница 9: ...e front scroll housing until the lock button snaps into the desired detent position B Fig 9 HOW TO HOLD SAW The metal parts of the saw blade and pivoting guide shoe may be made live if the blade cuts...

Страница 10: ...SPEED The saw is equipped with a variable speed control switch A Fig 11 0 to 2900 SPM As the switch trigger is squeezed the speed of the saw blade increases The lower speeds are recommended for most m...

Страница 11: ...iprocating saw is used much the same as a hand saw in that it is moved toward the operator during the cutting operation However since the blade cuts on the up stroke instead of the down stroke as in t...

Страница 12: ...lly blow out all air passages with dry compressed air All plastic parts should be cleaned with a soft damp cloth NEVER use solvents to clean plastic parts They could possibly dissolve or otherwise dam...

Страница 13: ...lly require servicing or replacement of parts due to wear from normal use These operations including brush inspection and replacement should ONLY be performed by either an AUTHORIZED PORTER CABLE SERV...

Страница 14: ...e Centers or Authorized Service Stations ANY IMPLIED WARRANTY INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WILL LAST ONLY FOR ONE 1 YEAR FROM THE DATE OF PU...

Страница 15: ...stributeur Porter Cable Delta centre de service agr ou centre de service d usine Porter Cable Delta Si vous n avez acc s aucun de ces centres appeler le 888 848 5175 et on vous dirigera vers le centre...

Отзывы: