SPECIFICATIONS
Model No.
C2004
Bore
1.875" (47.6 mm)
Stroke
1.250" (31.8 mm)
Voltage/Hz-Single Phase
120/60
Minimum Branch Circuit Requirement
15 amps
Branch Circuit Fuse Type
Time Delay
Air Tank Capacity
4 Gallons (15.1 liters)
Approximate Cut-in Pressure
135 psig
Approximate Cut-out Pressure
165 psig
SCFM @ 90 psig
2.6 *
Regulated Pressure Rating (Approximate) 3–150 psi
Quick Connect Type
1/4" (6.4 mm) Industrial
Noise Level
75.5 dBA +
* Tested per ISO 1217
+Tested per ISO 3744:1995
Refer to Glossary for abbreviations.
DECLARED NOISE EMISSION VALUES PER ISO 3744
Noise Emission Values
Sound Pressure Level:
LpA = 75.5 dBA re 20μPA
Uncertainty in the Sound
Pressure Level:
KpA = 3.0 dBA re 20μPA
Sound Power Level:
LwA = 88.0 dBA re 1 pw
Uncertainty in the Sound
Power Level:
KwA = 3.0 dBA re 1 pw
The sum of the emission value and the uncertainty is the limit below which there is
a 95% confidence the value of a single tool will lie below when the tool is new.