background image

2 - ENG

N003568

SAFETY GUIDELINES - DEFINITIONS

This manual contains information that is important for you to know and under-

stand. This information relates to protecting YOUR SAFETY and PREVENTING 

EQUIPMENT  PROBLEMS.  To  help  you  recognize  this  information,  we  use  the 

symbols below. Please read the manual and pay attention to these symbols.

Indicates  an  immi-

nently  hazardous  sit-

uation which, if not avoided, 

will

 result 

in 

death or serious injury

.

Indicates  a  potentially 

hazardous  situation 

which,  if  not  avoided, 

may

  result  in 

minor or moderate injury.

Indicates a potentially  

hazardous  situation 

which,  if  not  avoided, 

could

  result  in 

death or serious injury.

Used without the safety 

alert  symbol  indicates 

a  potentially  hazardous  situation  which, 

if  not  avoided, 

may

  result  in 

property 

damage.

IMPORTANT SAFETY INSTRUCTIONS

This  product  contains  chemicals  known  to  the  State  of 

California to cause cancer, and birth defects or other repro-

ductive harm. Wash hands after handling.

Some  dust  contains  chemicals  known  to  the  State  of 

California to cause cancer, birth defects or other reproduc-

tive harm such as asbestos and lead in lead based paint.

Do  not  operate  this  unit  until  you  read  and

  

understand  this  instruction  manual  for  safety,  

operation and maintenance instructions.

SAVE THESE INSTRUCTIONS 

HAZARD

 

 

 RISk OF ExPLOSION OR FIRE

WHAT CAN HAPPEN

HOW TO PREVENT IT

•  It is normal for electrical con-

tacts within the motor and pres-

sure switch to spark.

•  Always operate the compressor in a 

well ventilated area free of combustible 

materials, gasoline, or solvent vapors.

•  If electrical sparks from com-

pressor come into contact with 

flammable vapors, they may 

ignite, causing fire or explosion.

•  If spraying flammable materials, locate 

compressor at least 20' (6.1 m) away 

from spray area. An additional length of 

air hose may be required.

•  Store flammable materials in a secure 

location away from compressor.

Содержание C2002

Страница 1: ...Espa ol P gina 40 C2002 AIR COMPRESSOR Oil free pump Compresor de aire La pompe sans huile Compresseur d air La bomba sin aceite Instruction manual Manuel d instructions Manual de instrucciones www de...

Страница 2: ...icals known to the State of California to cause cancer and birth defects or other repro ductive harm Wash hands after handling Some dust contains chemicals known to the State of California to cause ca...

Страница 3: ...e air tank Breathing these contaminants can cause serious injury or death Air obtained directly from the compres sor should never be used to supply air for human consumption In order to use air produc...

Страница 4: ...authorized modifications to the safety valve or any other components which control air tank pressure The air tank is designed to withstand specific operating pressures Never make adjustments or parts...

Страница 5: ...duct could result in serious injury or death from electrocution Refer to Grounding Instructions para graph in the Installation section Make certain that the electrical circuit to which the compressor...

Страница 6: ...removed Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts Air vents may cover moving parts and should be avoided as well Attem...

Страница 7: ...cure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations HAZARD risk from noise What can h...

Страница 8: ...pressure Branch Circuit Circuit carrying electricity from electrical panel to outlet DUTY CYCLE This air compressor pump is capable of running continuously However to prolong the life of your air com...

Страница 9: ...nding plug and a 3 slot recep tacle that will accept the plug on the product in good condition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gauge number decreases 12 AWG and 10...

Страница 10: ...pressure Safety Valve If the pressure switch does not shut off the air compressor at its cut out pressure setting the safety valve will protect against high pressure by popping out at its factory set...

Страница 11: ...ure Risk of Unsafe Operation Serious damage may result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when...

Страница 12: ...bration is noticed stop the compressor immediately and have it checked by a trained service technician The compressor is ready for use MAINTENANCE Customer Responsibilities Before each use Daily or af...

Страница 13: ...e The air compressor can now be stored NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned the reinstalled SERVICE AND ADJUSTMENTS ALL MAINTENANCE AND REPAIR...

Страница 14: ...e by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see Replacement Parts in the Service section or purchase a standard hose clamp at a local hardware s...

Страница 15: ...com You can also order parts from your nearest factory owned branch or by calling our Customer Care Center at 1 888 848 5175 to receive personalized support from highly trained technicians SERVICE AN...

Страница 16: ...high Contact a Trained Service Technician Air leaks at fittings Tube fittings are not tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Over...

Страница 17: ...conditions while accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Decrease amount of air usage Compressor is not large enough for ai...

Страница 18: ...Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Extension cord is wrong length or gau...

Страница 19: ...CE D AU MOINS 20 PIEDS DE LA SURFACE VAPORISER NE PORTEZ PAS LE COMPRESSEUR ET NE L UTILISEZ PAS NI AUCUN AUTRE APPAREIL LECTRIQUE PROXIMIT DE L AIRE DE VAPORISATION NE FUMEZ JAMAIS QUAND VOUS VAPORIS...

Страница 20: ...Works Jet Lock Job Boss Kickstand LASERLOC LONG LASTING WORK LIFE MAX FORCE MAX LIFE Micro Set Midi Lathe Monsoon MONSTER CARBIDE Network OLDHAM Omnijig PC EDGE Performance Crew Performance Gear Pocke...

Отзывы: