background image

PART #

DESCRIPTION

PART #

DESCRIPTION

1

BASE-CYCLONE

CADDY FRAME

19 PAD6022.5/G

6"x12"x22" KUUL PAD FOR CYCLONE

2

BLOWER-01

BLOWER HOUSING

20 PAD6022.7G

6"x7"x22" KUUL PAD FOR CYCLONE

3

BLOWER-WHL-01

BLOWER WHEEL

21 POLY-FTG-06

90 DEG. FITTING FOR SIGHT TUBE

4

BONNET-05

BONNET

22 POWERCORD-02

10ft POWER CORD W / DOME STRAIN RELIEF

5

BOX-UL-02

2 SPD UL ELECTRICAL BOX

23 PUMP-BRACKET-#4

ALUM. BAR PUMP BRACKET

6

CAPACITOR-01

PSU 25-30 CAPACITOR

24 PUMP-CYC-3

CYCLONE PUMP - OK400

7

CAPBOOT-01

WATER PROOF BOOT FOR CAPACITOR

25 S-006

TEC SCREW S006

8

CASTER-3-L

3" LOCKING CASTERS

26 S-009

10/24 x 3/3 TRUSS HEAD SCREW

9

CASTER-3-NL

3" CASTERS

27 S-014

5/16 x 1" TRUSS HEAD SCREW

10

CLAMP-01

1/2" WIRE SPRING CLAMP

28 S-017

5/16 - 18 x 1.5" TRUSS HEAD SCREW

11

CTRL-2SPD-01

2-SPEED SWITCH ASSEMBLY

29 SPRAY-CYC-01

16" SPRAY BAR 

12

CTRL-VLV-BRKT-1

VALVE-01 MOUNTING BRACKETS

30 SPRAY-ACC-04

SPRAY BAR CLIP

13

DRAIN-PLUG-01

DRAIN PLUG

31 SWITCHPL-2SPD

2 SPEED SWITCH PLATE

14

FLAP-05

FLAP

32 TOG-BOOT-01

RUBBER TOGGLE SWITCH BOOT (2)

15

FLOAT-CYC-03

FLOAT VALVE FOR CYCLONE UNITS

33 TUBE-01

PUMP TO SPRAY BAR TUBING

16

LOUVERS-CYC-16

CYCLONE 3000 LOUVER W/MESH

34 TUBE-03

SIGHT TUBE

17

MOTOR-013-07B

1/3 HP - 2SPD MOTOR (BO)

35 VALVE-01

PUMP TO SPRAY BAR CONTROL VALVE

18

PAC-PLB-14

INLET HOSE ADAPTER

PACCYC04

29

33

20

33

35

28

4

14

26

30

13

3

6

34

21

17

2

15

18

1

25

23

10

10

16

5

11

31

32

27

28

9

8

22

19

14

7

8

9

12

24

PACCYC04A

CYCLONE 3200 PARTS

20

Содержание CYCLONE 1000 PACCYC06

Страница 1: ...PORTACOOL CYCLONE OWNER S MANUAL...

Страница 2: ...REQUENTLY ASKED QUESTIONS page 22 FOR ELECTRIC MODELS PAC2KCYC01 PAC2KCYC01A PACCYC02 PACCYC02A PACCYC03 PACCYC03A PACCYC04 PACCYC04A PACCYC05 PACCYC06 INCLUDES EXPORT MODELS PACCYC01 22050 PACCYC01 2...

Страница 3: ...t before starting the fan Check the water gauge to monitor water level in tank The water flow valve on each unit is set at max flow However ensure the knob is turned completely to the left before use...

Страница 4: ...CYCLONE 3000 OVERVIEW Control Panel Water Adjustment Valve Electrical Plug Locking Casters Hose Connec tion Adjustable Louvers Adjustable Louvers PAC2KCYC01 PAC2KCYC01A 3 Drain Plug...

Страница 5: ...CYCLONE 3200 OVERVIEW Control Panel Water Adjustment Valve Electrical Plug Locking Casters Hose Connection Adjustable Louvers Adjustable Louvers PACCYC04 PACCYC04A 4 Drain Plug...

Страница 6: ...CYCLONE 2000 OVERVIEW Control Panel Water Adjustment Valve Electrical Plug Locking Casters Hose Connection Adjustable Louvers Adjustable Louvers PACCYC02 PACCYC02A 5 Drain Plug...

Страница 7: ...CYCLONE 2200 OVERVIEW Control Panel Water Adjustment Valve Electrical Plug Locking Casters Hose Connection Adjustable Louvers Adjustable Louvers PACCYC03 PACCYC03A 6 Drain Plug...

Страница 8: ...Control Panel Water Tank Recessed Casters Drain Plug Electrical Cord Adjustable Louvers PACCYC06 CYCLONE 1000 OVERVIEW 7...

Страница 9: ...re performing inspections or repairs Plug into three prong grounded GFCI protected electrical receptacle only Do not step on or roll over power cord with heavy or sharp objects Do not operate evaporat...

Страница 10: ...ative cooler has its own set of operational specifications sizes weights voltage frequency current requirements etc Please ask for the specifications for your model from your distributor check the ser...

Страница 11: ...g water It may require up to a week to achieve maximum efficiency It is important to ensure that the spray bar is properly adjusted when first starting the water flow in the Portacool evaporative cool...

Страница 12: ...ed and the power disconnected the pads may be removed to allow cleaning of the water tank Dust may collect in the water tank over time Replace pads in correct airflow direction referring to the label...

Страница 13: ...rt with the center pad which can be tilted out from the top and lifted out of the drain trough The two pads to either side of the center pad may then be removed in the same manner To remove the two ou...

Страница 14: ...Make sure cooler is level clean spray bar D Pump not working D Clean or replace pump E Loose water connections E Check for leaks and correct Water draining from cooler 1 Float arm improperly adjusted...

Страница 15: ...ensure that the warranty is put into effect be sure to submit the warranty registration online or complete the warranty card that is shipped with your unit Please register online at http www portacoo...

Страница 16: ...parts 3 The customer distributor can call Tech Support to get an RMA number to send the defective part back to Portacool LLC Once the part is received by Portacool a replacement part will be sent at n...

Страница 17: ...CLONE1000 W EXTERNAL FRAME 10 CTRL 2SPD 01 2 SPEED SWITCH SET 31 SPIN FTG 02 1 4 SPIN FITTING FOR 16 UNIT 11 CYCLONE H 10 CYCLONE 1000 HOUSING BLACK 32 SPLASHGUARD C1 SPLASH GUARD CYCLONE1000 12 DRAIN...

Страница 18: ...400 7 CAPBOOT 01 WATER PROOF BOOT FOR CAPACITOR 24 S 006 TEC SCREW S006 8 CASTER 3 L 3 LOCKING CASTERS 25 S 009 10 24 x 3 3 TRUSS HEAD SCREW 9 CASTER 3 NL 3 CASTERS 26 S 014 5 16 x 1 TRUSS HEAD SCREW...

Страница 19: ...0 6 CAPACITOR 04 RUN CAPACITOR FOR CYCLONE2000 22 S 002 TEC SCREW S006 7 CASTER 3 L 3 LOCKING CASTERS 23 S 007 10 24 x 3 3 TRUSS HEAD SCREW 8 CASTER 3 NL 3 CASTERS 24 S 011 5 16 x 1 TRUSS HEAD SCREW 9...

Страница 20: ...T CYCLONE2000 6 CAPACITOR 04 RUN CAPACITOR FOR CYCLONE2000 22 PUMP CYC 3 CYCLONE PUMP OK400 7 CASTER 3 L 3 LOCKING CASTERS 23 S 002 8 x 3 4 TEK SCREW 8 CASTER 3 NL 3 CASTERS 24 S 007 5 16 18 x 3 4 TRU...

Страница 21: ...3 NL 3 CASTERS 27 S 014 5 16 x 1 TRUSS HEAD SCREW 10 CLAMP 01 1 2 WIRE SPRING CLAMP 28 S 017 5 16 18 x 1 5 TRUSS HEAD SCREW 11 CTRL 2SPD 01 2 SPEED SWITCH ASSEMBLY 29 SPRAY CYC 01 16 SPRAY BAR 12 CTR...

Страница 22: ...WIRING DIAGRAM 21...

Страница 23: ...e and frequency of use pads typically last up to five years Q WHAT IS THE DIFFERENCE BETWEEN EVAPORATIVE COOLING AND MISTING SYSTEMS A Misting units spray a shower of water into the air that will coll...

Страница 24: ...1 1 800 695 2942 ORDERS PORTACOOL COM TECHNICAL PARTS CONTACT 1 936 598 5651 1 866 COOLAID SUPPORT PORTACOOL COM Portacool LLC Manufacturer of Portacool portable evaporative coolers and K L Pads evapo...

Отзывы: