HYDRAULIC POWER UNIT G-18S10-54-W
OPERATION MANUAL
28
9
Shutdown and re-commissioning
The machine can be shut down for a usual maintenance period without any additional risks. No special maintenance or
conservation work is necessary. After a shutdown, a visual inspection must be carried out before a restart.
After shutdown time longer than three months, the hydraulic fluid must be checked for suitability before restarting.
10
Storage
The machine must be professionally packed for storage, otherwise there is a risk of injury or damage. The hydraulic unit should be
stored in a cool, dry place. The container for the hydraulic fluid must be filled completely. Ensure that all connections and opening
are well sealed.
Check for correct storage monthly.
If the hydraulic unit is stored for more than 3 months, the quality of the hydraulic fluid must be checked and replaced if necessary
before a new start-up.
11
Dismantling and disposal
Before dismantling or disposal, the machine must be decommissioned. This must be followed by draining the hydraulic fluid and
properly disposing it.
Dismantling is to be carried out in the following order:
1.
Depressurize the system
2.
Remove the hydraulic hose connections. Ensure that hydraulic fluid contained in the hoses is caught and properly disposed
of.
3.
Drain the hydraulic fluid and dispose of it properly.
4.
Disassemble the machine and dispose of the components properly.
The system disassembly and disposal must be carried out in accordance with the legal and official regulations.