REV
. 032017
10
S3.2 Temperature set point check (SET POINT display)
1. Press the SET button and release it immediately. The display shows the temperature set
point.
2. Press the HOME button and release it immediately or wait for 60 seconds, when the
display returns to the main menu.
S3.3 Temperature set point control
1. Press the SET button and release it immediately.
2. Press the ENTER button until the temperature set point starts flashing.
3. Change the value by pressing the UP or DOWN arrow key within 60 seconds.
4. Save the new set point by pressing the ENTER button for AT LEAST 2 SECONDS or wait
for 60 seconds.
5. Return to the main menu by pressing the HOME button.
S3.4 Temperature alarm limits
The inside temperature of the cabinet is controlled based on the set temperature value
taking into consideration the running and rest periods of the machinery. To ensure safe
storage of the products, the cabinet is equipped with temperature alarm function. It alarms
automatically if the internal temperature falls below the alarm limit (+ 2°C) or exceeds the
alarm limit (+ 8°C) staying outside these limits continuously for the time set to tempera-
ture alarm delay (15 min). This delay has been chosen by the manufacturer. It is so short
that the change of air temperature does not cause such a change of the product tem-
perature that would risk its safety. These alarm limits and delays can be changed in the
settings according to the instructions of the help menu.
S3. Daily use
Temperature
Set Value
Alarm Low
Alarm Up
Lorem ipsum