Value of On-Command (Parameter Number 3, Parameter Size 1)
Value
Description
0 — 99
(Default 99)
Value of Off-Command (Parameter Number 4, Parameter Size 1)
Value
Description
0 — 99
(Default 0)
Command Classes
Supported Command Classes
•
Basic (version 1)
•
Binary Switch (version 1)
•
Binary Sensor (version 2)
•
Association Group Information (version 1)
•
Device Reset Locally (version 1)
•
Z-Wave Plus Information (version 2)
•
Configuration (version 1)
•
Alarm (version 5)
•
Manufacturer Specific (version 2)
•
Powerlevel (version 1)
•
Firmware Update Meta Data (version 3)
•
Battery (version 1)
•
Association (version 2)
•
Version (version 2)
Controlled Command Classes
•
Basic (version 1)
Z-Wave Technical Data
Battery Type
1 / 2 AA
Frequency
868/869 MHz (SRD Frequency Band according EN300220)
Wireless Range
up to 100 m outdoor, 40 m in buildings
Explorer Frame Support Yes
SDK
6.51.6
Device Network Role
Reachable Sleeping Slave (RSS)
Device Type
Sensor
Routing
No
Firmware Version
1.0