Node Information Frame 

The Node Information Frame is the business card of a Z-Wave device. It contains information about 
the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed 
by sending out a Node Information Frame. Beside this it may be needed for certain network operations 
to send out a Node Information Frame. 

A simple click on the 'Inclusion Button' sends a NIF. 

Associations 

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling 
another device is called 

association

. In order to control a different device, the controlling device needs 

to maintain a list of devices that will receive controlling commands. These lists are called 

association 

groups 

and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In 

case the event happens all devices stored in the respective association group will receive a common 
wireless command. 

Association Groups: 

Lifeline (max. nodes in group: 10) 

Alarm Reports (max. nodes in group: 10) 

Switching Command when Alarm (max. nodes in group: 10) 

Configuration Parameters 

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration 
can adapt the function better to user needs or unlock further enhanced features. 

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 

128 

 255 the value sent in the application shall be the desired value minus 256. For example: to set 

a parameter to 200

 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two 

byte value the same logic applies: Values greater than 32768 may needed to be given as negative 
values too. 

Siren alarm sequence interval (Parameter Number 1, Parameter Size 1)

The additional siren is 

creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and 
partly off. This parameter defines the total length of the interval in seconds. 
 

Value 

Description 

6 — 129 

seconds  (Default 10) 

 
Siren alarm tone length (Parameter Number 2, Parameter Size 1)

The additional siren is creating a 

different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This 
parameter defines the total length of the sound versus silence within this interval. Please make sure 
this value is always smaller (shorter time) than parameter 1 that defines the whole sequence. 
 

Value 

Description 

1 — 99 

seconds (Default 8) 

 