![Popp Ei600ZW Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/popp/ei600zw/ei600zw_quick-start_1579758001.webp)
Ei600ZW – Z-Wave Module for 10 Year Smoke Sensor with Siren
Quick Start
This device is a combination of a Z-Wave sensor (smoke sensor) and a Z-Wave actuator.
Pressing the button 'Inclusion Button' for one second adds (includes) and removes (excludes)
the device from/to the Z-Wave network.
Please refer to the chapters below for detailed information about all aspects of the product.
Product description
This product combines a certified '10 year' stand-alone smoke detector with a plug-in Z-Wave module
to form a wirelessly reporting smoke sensor plus wirelessly controllable indoor siren. The smoke
detector is certified by the VdS for Q quality and DIN EN 14604 and satisfies all contemporary legal
requirements.
The High-End 10 year smoke detector offers a test button conveniently accessible even with a broom
stick when mounted on the sealing. The smoke chamber is monitored electronically to avoid any
malfunction and wrong alerts. The device will also report its End of life to make sure it is getting
replaced on time.
The device is a secure Z-Wave Plus device and can be used in one wireless Z-Wave network with
other certified devices regardless of origin and brand. It supports secure communication if the central
controller supports secure communication as well. Even if included securely the device is able to
communicate unsecured with devices included unsecure using the association groups 2 and 3.
Installation Guidelines
Please refer to the installation guide of the smoke sensor for
information about how and where the smoke sensor should be
installed. The installation guide complies with the norm DIN EN
14676.
•
The first step is to mount the mounting base on the desired
place in the home using screws.
•
Remove the battery isolation strip from the wireless module.
The red LED will start blinking.
•
Include the Smoke Sensor into your existing Z-Wave based
Smart Home Network using the 'Inclusion button'.
•
Place the Smoke Detector on the mounting base and turn
clockwise. Now the Smoke detector is armed.
•
Battery Change: The battery of the wireless module will be empty much earlier than the 10
years soldered in battery of the Smoke Sensor. To replace the battery, remove the Smoke
detector, pull off the wireless module from the smoke sensor. Then you can replace the 1/2 AA
battery and re-plug the wireless module.