background image

  

7

 

15.2. SX2 SYSTEM - water and air system

• Water massage

- 4 

fi

 xed back nozzles,

- 2 

fi

 xed foot nozzles (excluding Klio Asymmetric 140 x 80),

- 4 

fl

 at side nozzles with the option to direct water stream,

- independent control of back/side/foot massage intensity through aeration,
- water level sensor that prevents the pump from running dry,
- drain for removing water from the water massage system after bath.

• Water massage intensity control knobs

- bathtub top includes control knobs for adjusting air 

fl

 ow that adds aeration to water massage.

The control knobs direct air to side nozzles, back nozzles and foot nozzles.

• Air massage:

- system of air ducts in the bathtub,
- drain for removing water from the air massage system after bath,
- automatic hot air drying of the air system after bath.

• Chromotherapy

- multi-color LED spotlight.

SX2 hydro-massage system control

Proper activation or deactivation of features is always con

fi

 rmed with a beep.

System activation:

Touch the  

 symbol once to activate the hydro-massage system (all icons on the control panel 

as well as the LED light with automatic color changer will be switched on). 

Touch the 

 symbol again to deactivate the entire system.

Water massage:

The bathtub is equipped with a water level sensor to prevent the water massage pump from running 
dry. If the water level is below the required level, the pump will not start.

Touch the 

 symbol once to activate the water massage pump.

Touch the 

 symbol again to deactivate this feature.

The massage switches off automatically after 30 minutes. The system will then wait until you switch it back on or empty 
the bathtub.

Air massage:

Touch the 

 symbol once to activate the air massage pump. Touch the 

 symbol again to deactivate this feature.

The massage switches off automatically after 30 minutes. The system will then wait until you switch it back on or empty 
the bathtub.

Blowing through air ducts:

The air nozzles are automatically blown through and dried 30 minutes after draining water from the bathtub (for 5 
minutes), even if none of the features was activated.

If the bathtub was fi lled with a small amount of water, the water level sensor will not detect it. That is why, once 
you empty the bathtub, activate the blower for ca. 1 minute manually to blow through air nozzles and remove 
remaining water.

Содержание Klio asymmetric 140x80

Страница 1: ...Bathtub with the SX hydro massage system Klio rectangular 160 x 700 170 x 700 Klio asymmetric 140 x 800 150 x 100 163 x 103 Klio symmetric 133 x 133 140 x 140 Instruction manual Warranty...

Страница 2: ...ING TO THE WATER SUPPLY 4 11 CONNECTING TO THE POWER SUPPLY 4 12 TESTING BATHTUB LEAKPROOFNESS DURING INSTALLATION 4 13 PROPER INSTALLATION 4 14 INSTALLING PANEL ENCLOSURE 5 15 SYSTEMS AND THEIR CONTR...

Страница 3: ...clean and pleasant bathing Disinfecting the water and air system Every 2 to 4 weeks depending on the frequency of bathtub use fill the bathtub with clean cold water above the nozzle level and add 50...

Страница 4: ...st be connected to power permanently For safety reasons the bathtub power cord should be connected to power using only an electrical connection secured with a residual current device RCD with rated cu...

Страница 5: ...nder the enclosure after installation When installing manufacturer s suggested enclosures set enclosure spacer screws located in the aluminum bathtub frame attach pressure springs to holes in the bott...

Страница 6: ...ub is equipped with a water level sensor to prevent the water massage pump from running dry If the water level is below the required level the pump will not start Touch the symbol once to activate the...

Страница 7: ...ell as the LED light with automatic color changer will be switched on Touch the symbol again to deactivate the entire system Water massage The bathtub is equipped with a water level sensor to prevent...

Страница 8: ...of the whirlpool system operation water massage or the light function active the control panel will be automatically locked To unlock the panel hold your finger on any function button until the beep w...

Страница 9: ...surface smooth rub it with circular moves and then apply a wax based car body polish thus ensuring high gloss Problem Possible cause Procedure Massage systems do not work Interrupted power supply Che...

Страница 10: ...ropriate officially recognized certificates that confirm their compliance with local safety regulations e g electrical or water supply drain qualifications Small children should not use a hydro massag...

Страница 11: ...11 KLIO 140x80 bathtub KLIO 150x100 bathtub...

Страница 12: ...12 KLIO 163x103 bathtub KLIO 133x133 bathtub...

Страница 13: ...13 KLIO 140x140 bathtub...

Страница 14: ...ranty becomes void in the following cases mechanical damage of accessories mechanical damage of product surface user s own repairs and modifications installation of other devices on the product except...

Страница 15: ...SERIAL NUMBER PRODUCTION DATE RATED POWER CONSUMPTION REQUIRED CURRENT PROTECTION THERMAL PROTECTION CLASS QUALITY CONTROL F DEALER date of sale dealer s signature and stamp ELECTRICIAN S INSTALLER S...

Страница 16: ...a pl e mail infolinia roca pl ROCA POOL SPA is committed to constant improvement of its products and reserves the right to introduce changes to the specification and colors without prior notification...

Отзывы: