HOW A HIGH RATE MEDIA 

FILTER WORKS

The filter pump draws water from the pool and forces it under pressure into the multi-function innoValve where 
it is directed into the top of the filter tank via an overdrain diffuser. The water then flows down through the 
media bed, into the underdrain and back to the pool.

The  action  of  the  water  containing  suspended  particles  passing  through  the  filter  bed  causes  the  larger 
particles to be trapped and retained by the Diamond Kleen. Some of the very small particles may, however, pass 
completely through the filter and return to the pool, but in the process will have gained an electrostatic charge 
due to their high velocity over the media. This charge causes these particles to be attracted together to form 
clusters which are then large enough to be trapped by the Diamond Kleen on their next pass through the filter.

This is a normal characteristic of all high rate media filters.

As the quantity of suspended particles trapped in the media bed increases, the passage of water becomes 
progressively  restricted,  but  this  also  results  in  an  improvement  in  filtration  fineness.  However  when  this 
restriction to flow becomes excessive (as indicated by the rise in gauge pressure) the filter must be cleaned to 
restore a normal flow of water.

Cleaning is achieved by reversing the flow of water so it flows upwards through the media bed causing the 
individual grains of filter media to become buoyant and allow the bed to expand and release the trapped dirt 
particles which are then flushed out of the filter to the waste drain. This process is called BACKWASHING.

DELIVERY OF YOUR MEDIA FILTER

Each Poolrite filter/pump is delivered in two cartons as follows:

CARTON 1

 Factory assembly filter includes:
- Lateral
- Tank
- Clamp bands
- Gasket
-  Installation & Owners Manual 

with Warranty Card.

CARTON 2

Factory assembly innoValve includes:
- innoValve Multiport Valve
-  Three 50 x 50mm take-off 

unions with ‘O’ Rings.

- Three 50 x 40mm reducing bushes.

3

Содержание innoSphere 630

Страница 1: ...OWNERS MANUAL...

Страница 2: ...of several years of research and development at Poolrite to produce a filter control valve which provides far less noise and restriction to water flow is easier to operate and requires no maintenance...

Страница 3: ...Filter 3 Attention Installer 4 Installation Instructions 5 Starting Up Procedure 7 Priming The Pump Starting The Filter Backwashing 8 Filter By Pass Waste 8 Recirculating 9 Valve Closed 9 Vacuum Clea...

Страница 4: ...teristic of all high rate media filters As the quantity of suspended particles trapped in the media bed increases the passage of water becomes progressively restricted but this also results in an impr...

Страница 5: ...nitial vacuum cleaning of the pool it is wise to use a filter sock in the pump strainer basket to prevent excess debris damaging the pump impeller seal 8 Do not operate the filter system in FILTER mod...

Страница 6: ...ALLATION INSTRUCTIONS IMPORTANT Tighten all backnuts by hand only DO NOT USE TOOLS Pump Filter should be installed between 1 0 metre above or 1 0 metre below mean pool water level for correct operatio...

Страница 7: ...lve then twist and pull standpipe downwards until separated 8 Place valve and rubber gasket in a clean place 9 Re position bottom of standpipe assembly in bottom of tank 10 While holding standpipe cen...

Страница 8: ...If air is still present the suction pipe to the skimmer should be checked 7 After pump has fully primed run for approximately three 3 minutes or until water in Sight Glass becomes clear 8 Switch pump...

Страница 9: ...re gauge should be reading in the lower portion of the green FILTER band IMPORTANT Before and after backwashing check that the pool water level is correct FILTER BY PASS WASTE If the pool is often ove...

Страница 10: ...vent the filter contents draining back through the pump when the lid is removed to enable cleaning of the strainer basket Ensure innoValve is in the FILTER position before restarting the pump PRESSURE...

Страница 11: ...rrectly fitted and tightened Water Drains Back to Pool when Pump Switched Off Check pump lid for leaks Check SMARTVALVE for leaks Check backnuts are tight on all pipe connectors Pump Loses Suction Che...

Страница 12: ...d Kleen media M10 fine kgs 75 5 Bags Diamond Kleen media M20 coarse kgs 30 2 Bags Recommended Pump Model SQI 500 SQI 600 EP 750 EP 930 Gemini Factory Pressure tested in excess of 300 kPa Maximum Worki...

Страница 13: ...Internal Fittings or Plumbing etc 5 The Warranty is void if the following are not adhered to The equipment must be installed and used in accordance with the instructions supplied The Equipment is des...

Страница 14: ...urchaser Address Purchased From Date Equipment and Model IMPORTANT This Warranty Card should be filled in and returned to Marco Engineering Pty Ltd PO Box 1491 Browns Plains QLD 4118 Australia KEEP WI...

Страница 15: ...14...

Страница 16: ...The only supplier of genuine Poolrite spares in the world Marco Engineering Pty Ltd P 07 3803 6222 F 07 3803 6353 E poolrite evolvegrp com PO Box 1491 Browns Plains QLD 4118 AUSTRALIA www poolrite com...