background image

OWNERS MANUAL

Содержание innoSphere 630

Страница 1: ...OWNERS MANUAL...

Страница 2: ...of several years of research and development at Poolrite to produce a filter control valve which provides far less noise and restriction to water flow is easier to operate and requires no maintenance...

Страница 3: ...Filter 3 Attention Installer 4 Installation Instructions 5 Starting Up Procedure 7 Priming The Pump Starting The Filter Backwashing 8 Filter By Pass Waste 8 Recirculating 9 Valve Closed 9 Vacuum Clea...

Страница 4: ...teristic of all high rate media filters As the quantity of suspended particles trapped in the media bed increases the passage of water becomes progressively restricted but this also results in an impr...

Страница 5: ...nitial vacuum cleaning of the pool it is wise to use a filter sock in the pump strainer basket to prevent excess debris damaging the pump impeller seal 8 Do not operate the filter system in FILTER mod...

Страница 6: ...ALLATION INSTRUCTIONS IMPORTANT Tighten all backnuts by hand only DO NOT USE TOOLS Pump Filter should be installed between 1 0 metre above or 1 0 metre below mean pool water level for correct operatio...

Страница 7: ...lve then twist and pull standpipe downwards until separated 8 Place valve and rubber gasket in a clean place 9 Re position bottom of standpipe assembly in bottom of tank 10 While holding standpipe cen...

Страница 8: ...If air is still present the suction pipe to the skimmer should be checked 7 After pump has fully primed run for approximately three 3 minutes or until water in Sight Glass becomes clear 8 Switch pump...

Страница 9: ...re gauge should be reading in the lower portion of the green FILTER band IMPORTANT Before and after backwashing check that the pool water level is correct FILTER BY PASS WASTE If the pool is often ove...

Страница 10: ...vent the filter contents draining back through the pump when the lid is removed to enable cleaning of the strainer basket Ensure innoValve is in the FILTER position before restarting the pump PRESSURE...

Страница 11: ...rrectly fitted and tightened Water Drains Back to Pool when Pump Switched Off Check pump lid for leaks Check SMARTVALVE for leaks Check backnuts are tight on all pipe connectors Pump Loses Suction Che...

Страница 12: ...d Kleen media M10 fine kgs 75 5 Bags Diamond Kleen media M20 coarse kgs 30 2 Bags Recommended Pump Model SQI 500 SQI 600 EP 750 EP 930 Gemini Factory Pressure tested in excess of 300 kPa Maximum Worki...

Страница 13: ...Internal Fittings or Plumbing etc 5 The Warranty is void if the following are not adhered to The equipment must be installed and used in accordance with the instructions supplied The Equipment is des...

Страница 14: ...urchaser Address Purchased From Date Equipment and Model IMPORTANT This Warranty Card should be filled in and returned to Marco Engineering Pty Ltd PO Box 1491 Browns Plains QLD 4118 Australia KEEP WI...

Страница 15: ...14...

Страница 16: ...The only supplier of genuine Poolrite spares in the world Marco Engineering Pty Ltd P 07 3803 6222 F 07 3803 6353 E poolrite evolvegrp com PO Box 1491 Browns Plains QLD 4118 AUSTRALIA www poolrite com...

Отзывы: