2.9. Safety
2.9.1. Alarms and alerts
SAFETY
DEFAULT
CONFIGURATION
AUTOMATIC OPERATIONS
UPON ACTIVATION
DISMISSAL*
Message
displayed
Immediate stop
of chlorine dosing
and/or pH regulation
Alarms
Activated
Yes
Press the
OK
or
button (press
or press and hold, depending on
whether it is an alarm or alert).
Alerts
Activated
No
*
The corresponding alarm or alert is maintained while the detected fault remains in place, and the corresponding
message reappears a few moments after dismissal.
MESSAGE
DISPLAYED/FAULT
DETECTED
IMMEDIATE
AUTOMATIC STOP
POSSIBLE CAUSE
CHECKS AND REMEDIES
OPTION TO
DISABLE
VIA THE
menu
Chlorine
dosing
pH
regulation
Yes
No
Unadjusted free
chlorine rate
measurement
Carry out an adjustment of the free
chlorine rate measurement.
Yes
Yes
No
Empty chlorine
container
Replace the chlorine container.
Yes
is activated
No
Yes
pH corrector
container empty
Replace the pH corrector container.
Yes
is activated
Yes
Yes
Insufficient water
flow
Check that:
- the flow sensor is properly
connected to the electronics unit.
- the flow sensor is activated
(see
sensor settings)
.
- the valves on the filtration circuit are
open.
- the filter pump is working properly.
- the filtration circuit is not blocked.
- there is enough water in the pool.
No
Yes
No
Incorrect or
defective electrical
connection of the
amperometric
probe
Check:
- the connection of the amperometric
probe to the electronics unit.
- the condition of the amperometric
probe cable.
- internal wiring to the amperometric
probe.
- the state of the terminal block
internal to the amperometric probe.
No
Amperometric
probe defective or
at the end of its life
Change the amperometric probe.