11
2.7.
Chlorine dosing
2.7.1.
Memorising the last refill/change of electrolyte gel
The electrolyte gel relates to the amperometric probe (see the manual provided with the probe).
Menu
Sub-menu
Principle
Confirmation
Date of last refill/change
=
Date of last confirmation
Press twice on
OK
:
appear.
2.7.2.
electrolytic gel on the same day this alert is activated.
Menu
Sub-menu
Activation delay after the last refill/change of electrolyte gel
Possible settings
Default setting
From 30 to 180 days, in 30-day increments
90 days
2.7.3.
Calibrating the free chlorine rate measurement
Menu
Possible settings
Default setting
From 0.1 to 5 ppm, in increments of 0.1 ppm
Current measurement
2.7.4.
Selection of the chlorine dosing mode
Menu
Possible
settings
Meaning
Indicator viewable
on the display by default
Default
setting
CL
Chlorine dosing by amperometric
control and according to the CL setpoint
CL
MANU
Hourly chlorine dosing
OFF
Switching off the chlorine dosing
or
(on the display by default)
Depending on the settings made, some menus may not appear.
2.7.5.
Specification of the chlorine concentration
Menu
Possible settings
Default setting
From 5 to 48°, in increments of 1°
48°
2.7.6.
Setting the chlorine setpoint
Menu
Possible settings
Default setting
From 0.1 to 5 ppm, in increments of 0.1 ppm
1 ppm