13
Menu
Sensor
Setting
Possible settings
Default setting
Settings
Sensors
CL container
Mode
•
OFF
•
ON
ON
Type
•
NO
•
NC
NO
pH container
Mode
•
OFF
•
ON
ON
Type
•
NO
•
NC
NO
XX container:
empty container sensor.
Type:
this parameter does not appear if the corresponding mode is set to OFF.
ON:
sensor activated.
OFF:
sensor disabled.
NO:
switch normally open.
NC:
switch normally closed.
Sensor activated
Configuration
Specific display
Dosing of chlorine
Regulation of pH
Empty CL container
Empty container
Alarm
Empty CL container
Stopped
Maintained
Container not empty
-
Maintained
Maintained
Empty pH container
Empty container
Alarm
Empty pH container
Maintained
Stopped
Container not empty
-
Maintained
Maintained
2.8.4.
Settings reset
Menu
Important warning
Settings
Reset. Sett.
I
Resetting the settings cancels all the settings carried out (factory configuration).