Mini LTE – PAPI004096 – MULTI1-FR-EN-IT-ES – Rev.0417
12
Adjust the current reversal time
Allows to adjust
the reversal time of the current going through the cell according to
water hardness. The recorded value is then flashing.
from Off to 16 h
Activate / Disactivate the automatic pool cover function
Chlorine production change according to pool cover closing
On / Off
Activate / Disactivate A1 alarm
*
:
Production default
*
In
Factory settings, A1 alarm is disabled. You can manually activate this function.
On / Off
5.3.1. Boost mode (depending on model)
To reach the adjusment menu press the
key for 5 s.
•
Select « bo » menu
•
Press 5s on the key to activate the BOOST mode.
•
The device shows « bo ».
Key allows to stop Boost mode at any time.
T
he boost mode is a preventive and not curative mode!
It is not possible to replace it by a classical shock treatment in the case of water of swimming pool unfit for the
bathing.
5.3.2. Adjustment of the polarity inversion time / Self cell cleaning (depending on model)
This device is equipped with a self-cell cleaning process by polarity inversion. For a better cleaning, these
inversions must be adjusted according to water hardness.
Adjust frequencies (code « In » in the adjustment menu):
TH (mg/l CaCo
3
)
0 - 50
50 - 120
120 - 200
200 - 400 400 – 600
>600
TH (°f)
0 - 5
5 – 12
12 - 20
20 – 40
40 - 60
> 60
Inversion frequencies (hours)
OFF
16
10
6
4
2
Important : The self-cell cleaning will not compensate a too high water hardness. Higher than 60°f TH, it’s
important to adjust the water balance first to reduce the water hardness.
A scaly cell because of wrong adjustment will not be warranty anymore.
5.4. pH menu
To access pH menu, device must display pH value.
Press 3s
key.
•
Select code (menu) with
and validate with
key.
•
Select the target value with
and validate with
•
Value stops flashing and display comes back on the main screen.
DUO
pH
-
/V
In
AL
Co
-
/V
-
/V
+/C
-
/V
-
/V
-
/V
-
/V
+/C
-
/V