6. INSTALLATION DIAGRAM
Ref #
Item
1
Pool Filter
2
Heat Pump
Ref #
Item
5
Cell Housing
6
pH Controller
IMPORTANT NOTES
The pump rating must not exceed 8amps.
Saltwater may damage electrical components in the Power Pack.
WARNING:
We DO NOT recommend the use of valves on the
inlet or outlet of the cell housing. If you do use a valve, then it is
important to ensure that the valve cannot deadhead (lock closed)
while the pump is running. It is the installer’s responsibility to ensure some form of flow
control is installed in this instance and it disables the pump.
ALWAYS ensure that pipe work and equipment do not allow gases generated from the
Cell to collect and build up in any part of the installation.
It is RECOMMENDED that the Cell Housing be installed horizontally to create a natural
gas trap that acts as a safety device. Installation in any other way may cause explosion,
injury or death if the installer does not allow for gas removal. A venturi pipe is installed/
molded within the Cell Housing design to eliminate any possible gas build up, although it
is always recommended to ensure proper installation to eliminate this from happening.
The Cell Housing must be installed in the RETURN pipework to the pool. It must always
be installed after the filter, gas heater, solar heating, or heat pump.
DO NOT apply priming fluid to the Cell Housing, it is not needed and may react with the
plastic.
Ref #
Item
3
Pool Pump
4
Chlorinator