Page 25
SETTING THE INBUILT POOL PUMP TIMER
The unit’s built-in pump timer is factory set to two ON TIMES each day. If the built-in pump
timer is not to be used (because an external pump timer is used), the built-in pump timer
must
be permanently turned off. (
see “Automatic Pump Timer Settings” on page 26)
If it is decided to turn off the automatic pool pump timer and use the manual switching of
the pool pump on a daily basis, this may result in unbalanced pool water that is not safe for
swimming. If necessary, obtain advice from a qualified pool maintenance technician.
PUMP ON MANUALLY
The following instructions apply if the unit’s built-in pool pump timer is used, and not a
separate pool pump timer:
To turn the pool pump on manually for 30 minutes - press keypad 1 until the
ON
light is
illuminated
To increase the manual ON time:
Select
PUMP ON
and continue to hold down. After 5 seconds the length of time to run
manually can be seen in the top right-hand
side of the unit’s screen. This will increase
every few seconds. Release the keypad when the required length of time is reached.
PUMP OFF MANUALLY
The following instructions apply if the unit’s built-in pool pump timer is used, and not a
separate pool pump timer:
To manually turn the pool pump off for 30 minutes - press keypad 1 until the
OFF
light is
illuminated.
To increase the manual OFF time:
Select
PUMP OFF
and continue to hold down. After 5 seconds the length of manual off
time can be seen in the top right-hand
side of the unit’s screen. This will increase every
few seconds. Release the keypad when the required length of time is reached.
PUMP AUTOMATIC ON and OFF
The following instructions apply if the unit’s built-in pool pump timer is used, and not a
separate pool pump timer:
Automatic Readings:
Press and release keypad 1 until
AUTO
is illuminated.
The unit has daily factory pre-set ON and OFF times of:
P1: 8am to10am
P2: 6pm to 8pm.
P3& P4: Optional
– to operate pool pumps more than twice per day
It is a 24-hour clock. For example, 8pm reads as 20.00 hrs.
Pre-set pump times will automatically turn the pool pump ON and OFF.
Содержание Chemigem CM55
Страница 1: ...Commercial Semi commercial Water Management System User Manual...
Страница 11: ...Page 9...
Страница 18: ...Page 16...