![Pontec PondoSolar 150 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/pontec/pondosolar-150/pondosolar-150_translation-of-the-original-operating-instructions_1579098007.webp)
- EN -
7
Scope of delivery
5
A
Quantity
Description
1
1
Filter housing
2
1
Pump with outlet and 5 m connection cable
3
4
Nozzle extension
4
1
Nozzle holder
5
4
Nozzle attachment
6
1
Solar module
7
1
Ground stake set
Intended use
PondoSolar 150, referred to as "unit", may only be used as specified in the following:
•
For creating a water fountain in a pond.
•
For operation with clean water.
•
Operate in accordance with instructions.
•
Operation under observance of the permissible water quality. (
→
Water quality)
The following restrictions apply to the unit:
•
Never use the unit with fluids other than water.
•
Never run the unit without water.
•
Do not use for commercial or industrial purposes.
•
Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
•
Do not connect to the domestic water supply.
Installation and connection
How to proceed:
5
B
1. Assemble the nozzle unit and fit onto the pump.
– Adapt the number of nozzle extensions used to the depth of the pond.
2. Connect the connection cable to the solar module.
– Push the plug completely into the socket (up to the stop) to ensure that the connection is watertight.
– Switching on: Connect the pump to the solar module.
– Switching off: Disconnect the solar module from the pump.
3. Assemble the ground stake set and attach it to the solar module.
– Ensure that the connection cable is routed downwards.
4. Fix the pump underwater to a smooth, clean surface using the suction cups.
5. Install the solar module so that it is exposed to direct sunlight.
– Recommendation: Align the solar module to the sun to ensure maximum energy yield.
Remedy of faults
Malfunction
Cause
Remedy
Pump does not start.
No connection to the solar module.
Connect the pump to the solar module.
Correctly insert the connection cable.
The solar module is soiled.
Clean
The impeller unit is blocked
Clean
Insufficient or no pump delivery.
The filter is clogged.
Open the pump, remove and clean the filter.
The nozzle unit is clogged.
Remove and clean the nozzle unit.
The impeller unit is worn.
Replace
Insufficient sunlight
Direct sunlight