Operating functions
Switching the pump on/off
Proceed as follows
Information
Press the button briefly to turn the pump on or off.
When the pump is switched off, the display shows "OFF".
Increasing/decreasing power
Proceed as follows
Information
Press the desired button several times or press
and hold it to change the power.
When a button is pressed, the display automatically shows the power
values in percent(%).
Adjustable range: 1 % … 100 %
Increment: 1 %
The adjusted value is immediately adopted.
After 15 s without operation, the controller automatically switches to the
"W” display.
Displaying the current power value
Proceed as follows
Information
Briefly press the button to toggle the display.
Display "W"
Shows the current pump power value in watt
Tolerance: ±5 % of the max. power consumption.
Display "%"
Shows the current pump power value as a percentage.
Display range:
1
to
100
After 15 s without operation, the controller automatically switches to the
"W” display.
Malfunction remedy
Troubleshooting overview
Malfunction
Cause
Remedy
Pump does not start
No mains voltage
Check the mains voltage.
Check supply lines.
Pump not switched on
Switch the pump on at the controller
Pump does not transport
fluid
Filter housing clogged
Clean strainer casings
Excessively soiled water
Clean the pump. The pump automatically switches on again once the motor has
cooled down.
Pump is set too low
Increase the rotation speed of the pump at the controller
The impeller unit is blocked
Disconnect the power supply and remove obstacle. Then switch the pump on
again.
Insufficient delivered quan-
tity
Filter housing clogged
Clean strainer casings
Excessive loss in the supply lines
Select larger hose diameter
Adjust stepped hose adapter to hose diameter
Reduce hose length to minimum necessary
Avoid unnecessary connection elements
Pump is set too low
Increase the rotation speed of the pump at the controller
Pump switches off after op-
erating briefly
Excessively soiled water
Clean the pump. The pump automatically switches on again once the motor has
cooled down.
The impeller unit is blocked
Disconnect the power supply and remove obstacle. Then switch the pump on
again.
Pump has run dry.
Flood the pump. Fully submerge the pump for operation in the pond.