The real-time simulation technology is widely used in the power system. Different digital 

simulation system are developed such as RTDS, EDF and TEQSIM, etc. But no matter how 

the digital simulation or digital-analog model simulation changes, the power amplifiers are 

the main component in the system. 

The power amplifier for digital simulator in power system is required to have high linearity, 

quick response, be  available to all kinds of capacitive, inductive and resistive loads. 

Generally power amplifier consists of two types of amplifiers: linear power amplifier and 

switching power amplifier. The linear power amplifier has the strengths of high linearity, 

quick response, high accuracy, good electromagnetic compatibility and the weakness of bad 

performance in high current and high power cases. The switching power amplifier is quite fit 

in high current, high power devices with its strength of high efficiency, but it’s weak in 

linearity, small signal noise, DC offset, drift, transient response, load driving capability 

aspects, which are very difficult to fix. 

PA460Bi-L amplifier

 is specially designed for power electricity simulation and solves the 

high power problem  for linear power amplifier and accuracy problem for heavy current 

output. 

PA460Bi-L  amplifier 

has  six-phase current output. Each phase maximally outputs 15A 

RMS and maximum output power of 135VA. There is six-phase voltage output. Each phase 

outputs 120V RMS and maximum output power of 60VA. 

Содержание PA460Bi-L

Страница 1: ...NE 2021 This manual is the publication of PONOVO POWER CO LTD Any form of copy should obtain the consent of it The manual represents the technology status at publication time The product information d...

Страница 2: ...al Specifications for Voltage Amplifier 11 4 Functions of Current Amplifier 12 4 1 Basic Principle 12 4 2 Function 12 4 3 High Current Output 14 4 4 High Power Output 16 5 Functions of Voltage Amplifi...

Страница 3: ...m shaking 4 Generally it s not necessary to depress high power button high power button light should be off also 5 Never operate live signal and load wires with voltage or current output to protect th...

Страница 4: ...and operate the equipment in the place having explosive gas or water vapor 14 The 500V dangerous voltage can be in the equipment and please don t remove the cover by yourself 15 Please contact the ma...

Страница 5: ...nd authorized by local country could be used Ground The Instrument The instrument must be grounded safely with the supplied ground cable Observe All Terminal Ratings To avoid fire or shock hazard obse...

Страница 6: ...maintenance adjustment or replacement especially to circuits or accessories must be performed by authorized personnel Keep Well Ventilation Inadequate ventilation may cause increasing of temperature...

Страница 7: ...n electrostatic discharge protective area environment to avoid damages induced by static discharges Always ground both the internal and external conductors of the cable to release static before connec...

Страница 8: ...ated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interfer...

Страница 9: ...r power amplifier has the strengths of high linearity quick response high accuracy good electromagnetic compatibility and the weakness of bad performance in high current and high power cases The switc...

Страница 10: ...Storage temperature 25 70 C Related humidity 20 RH 85 RH Pressure 86 kPa 106kPa EMC Emission IEC 61000 3 2 3 EMC immunity IEC 61000 4 2 3 4 5 6 11 Safety IEC EN 61010 1 2010 UL 61010 1 2012 CAN CSA C2...

Страница 11: ...mplifier Current output 6x0 15A RMS Max output power 6x135VA at 15A Input Signal 0 5V RMS 7 07Vpek Differential input impedance 20k Gain 3A V Current accuracy 0 2 0 5 15A Current typical accuracy 0 1...

Страница 12: ...120V Max output power 6 60VA at 120V Input signal 0 6V RMS 8 5Vpek Differential input impedance 20k Gain 20V V Voltage accuracy 0 1 5V 120V Voltage typical accuracy 0 05 Harmonic distortion ratio 0 1...

Страница 13: ...s temperature is too high and will resume working when it is cooled down to a reasonable degree 5 Cooling fan When the temperature of the amplifier is quite low the fan will work at low speed for prol...

Страница 14: ...e front panel can cut off the signal input of the amplifier pressing the pause button to pause the output of the amplifier And resume the output after pressing Pause again 4 When the overheat protecti...

Страница 15: ...er User Manual 14 4 3 High Current Output PA460Bi L supports 3 current output simultaneous as 3 30A The wiring connection is made as below Note The output in each channel should be directly connected...

Страница 16: ...put short circuited IA Ia input short circuited IB Ib input short circuited IB Ib input short circuited IC Ic input short circuited IC Ic input short circuited Because the current signal input 2 group...

Страница 17: ...nerally it s not necessary to activate the high power output function because it may cause extra heat generated from amplifier 2 High power output function must be inactivated as soon as the job was d...

Страница 18: ...the amplifier reaches dangerous degree and will let the amplifier resume to work automatically when it has been cooled down to a reasonable level 5 Cooling fan Fan will work at low speed if amplifier...

Страница 19: ...3 Pause control function PAUSE The pause button on the front panel can cut off the signal input of the amplifier pressing the pause button to pause the output of the amplifier And resume the output a...

Страница 20: ...ge signal the Run indicator will be on 2 High power control button Press it to output current high power 3 Power switch Power ON OFF 4 Status indicators Overheat V Overload IA Overload IB Overload IC...

Страница 21: ...nected with the current input of the test object 7 Voltage output It is connected with the voltage input of the test object 8 Power socket Please use the power cable supplied by PONOVO 9 Earth ground...

Страница 22: ...ore energizing the amplifier Turn on the power on the front panel after all is ready 7 3 Current and voltage output 1 Press Pause button or send remote pause signal and correspond to the current volta...

Страница 23: ...ety never plug signal cable or load connection when there is current output 7 4 Turn Off After all testing is finished please terminate the simulator signal input press Pause button and turn off the p...

Страница 24: ...et the amplifier is required to have strictly inspections The test items are function inspection linearity load stability THD max output power amplitude frequency characteristic input output delay and...

Страница 25: ...sequence without prior notice to manufacturer or agent Pictures for reference only The amplifier Wiring Accessory Package contains the following articles The pictures are for reference 1 Current cable...

Страница 26: ...ts the amplifier with power supply socket PONOVO will provide relevant plug socket according to different countries NOTE D03 Adapter is mainly used in German Finland France Norway Sweden Poland South...

Страница 27: ...ad Specification 2 5mm 4m Amount 1 piece Earthing lead connects the amplifier with ground to ensure kit safety Notes In order to avoid static induction users should connect the equipment with ground r...

Отзывы: