PRODUCT SPECIFIC SAFEGUARDS

•  Do not operate the pump without water at any time, permanent damage may occur.
•  Be sure the equipment is submerged completely in the water. The depth should not be greater than 

6ft. 

•  The pump is designed to be used in a garden pond, fountain or freshwater aquarium.  It is not to be 

used in any other manner or purpose. The pump should only be used in clean water.  Do not use the 
pump in, or with, and chemicals such as sovent or gasoline. 

•  PondMAX High Flow Pumps are cooled by water flowing through the inside of the motor body. If the 

pump flow becomes restricted it will overheat and could cause permanent damage. Large tubing size 
is strongly recommended to deliver adequate water flow to cool the pump. The pump needs to be 
cleaned regularly to prevent the pump becoming blocked, thus causing the pump to overheat and 
burn out. This is not a warrantable event. It is strongly recommended not to select a pump that is too 
small for the application requirements. The flow rate through the pump needs to maintain more than 
half of the rated max flow. 

INSTALLATION - FILTER & WATERFALL PLUMBING GUIDE

•  When used to supply water to a biological filter, cascade or waterfall,ensure to use large enough 

tubing for the flow rate required. 

•  For best results, use the tubing size recommended in the table under “specifications” at the beginning 

of this manual. Larger tubing size is always recommended for high flow rate pumps.  Select the hose 
tail required for your tubing size and evaluate which step on the hosetail will be used. 

•  If you are using 2 inch hose and you are connecting it to a 1.5” - 2” hosetail, remember to saw off 

the smaller size connection (I.E.: 1.5” step). Otherwise it will create an unnecessary restriction in the 
plumbing system.

•  Now connect the tubing to the hose tail. Remember to use Stainless Steel hose clamps to fasten the 

hose on to the hosetail. This is to ensure that the pipe does not blow off later or leak at this point in 
the plumbing system.

•  Direct the hose in your desired direction. Connect tubing to the outlet.
•  Place the pump in desired location. Ensure the pump is on a stable surface that is free of sludge, sand 

and other debris.

•  Do not place the pump directly on the pond floor or in mud. It is recommended to place the pump on 

a raised surface.

The PX4500A has an adjustable flow rate so you can reduce the flow. 

•  On the PX4500A model the flow adjuster dial is on the back of the pump.  It must be set to one of 

the three settings to work.  Turn the flow adjuster dial to adjust the speed of the motor and the flow 
capacity. 

•  Manual operation mode is enabled when the arrow on the dial is aligned with one of the numbers 1, 2 

or 3, three (3) being the highest flow rate and one (1) being the lowest.

•  DO NOT PLACE THE ARROW BETWEEN TWO SETTINGS, THE PUMP WILL NOT WORK. 

 

PMAX PX20000_30000 Pumps Instructions.indd   4

26/9/19   11:22 am

Содержание PX4500

Страница 1: ...HIGH FLOW WATERFALL PUMP INSTRUCTION MANUAL US 888 868 1185 CAN 888 855 4551 DATE AUG 2019 v1 0US MODEL PX4500 PX4500A PMAX PX20000_30000 Pumps Instructions indd 1 26 9 19 11 22 am ...

Страница 2: ... application Open Vane Impeller Handles particles size up to 6mm of sediment Long Life Impeller Ceramic shaft is wear resistant and self lubricated by water Energy Efficient Exceptional low power consumption to water flow ratio Eco Friendly Exceptional low dB noise rating with low mechanical vibration Compatibility Suitable for fresh water submersible applications DESCRIPTION PX4500 PX4500A MAX WA...

Страница 3: ...length of the appliance Be sure the equipment is submerged completely in the water The depth should not be greater than 6ft Do not operate the pump if the appliance or any components of the system such as the power cable have been damaged Check appliance for defects regularly Always use a properly grounded power supply that is connected to a GFCI with a rated residual operating current not exceedi...

Страница 4: ...specifications at the beginning of this manual Larger tubing size is always recommended for high flow rate pumps Select the hose tail required for your tubing size and evaluate which step on the hosetail will be used If you are using 2 inch hose and you are connecting it to a 1 5 2 hosetail remember to saw off the smaller size connection I E 1 5 step Otherwise it will create an unnecessary restric...

Страница 5: ... of any blockage This is a colling channel for the motor 1 Clean the housing and pump with a suitable brush taking care to clean off sludge algae and debris 2 To maintain the impeller of the pump remove the impeller cover screws to separate the impeller cover from the pump motor body 3 Lift out the impeller assembly Take care not to break ceramic shaft The black disc behind the blades is part of t...

Страница 6: ...l The use of any other accessories or attachments might present a risk of injury to persons Only use the accessory or attachment for its stated purpose 6 5 4 3 1 2 7 8 1 Pump Base 2 Pump Body 3 Impeller Assembly 4 Impellor O Ring 5 Impellor Cover 6 Front Cage 7 Hose Tail 8 2 Pipe Connector PMAX PX20000_30000 Pumps Instructions indd 6 26 9 19 11 22 am ...

Страница 7: ...t underwater then plug in Refill if necessary Blocked impeller chamber or ceramic shaft is broken Clean the impeller Check for ware Replace if necessary Water Pump is noisy Blockage in pump Clear the blockage Impeller shaft worn out Replace impeller assembly Impellor broken Replace impeller assembly Water valve closed on the outlet Open the valve and allow water to flow Pump inlet is blocked Clear...

Страница 8: ...rranty Purchaser shall bear all shipping packing and insurance costs and all other costs excluding labor and parts necessary to effectuate repairs under this warranty This warranty is in lieu of all other express warranties which now or hereafter might otherwise arise with respect to this product Any and all limited warranties including the warranties of merchantability and fitness for particular ...