PondMAX PX4500 Скачать руководство пользователя страница 3

W A T E R G A R D E N I N G   T O   T H E   M A X

P O N D M A X . C O M

HIGH FLOW 

WATERFALL PUMP

BENEFITS

S

uitable for filtration, waterfalls and circulation in bodies of water, such as outdoor garden ponds, 

fresh water aquariums. aquaculture and indoor or outdoor water fountains. 
•  Your pump has a single moving part (impeller assembly) enabling easy cleaning and maintenance. 
•  The pump has intelligent circuitry that analyses the speed and torque of the motor. It will increase 

and decrease the energy usage to maximise efficiency. The soft start nature of the motor helps 
to avoid sudden pressure surges causing pipes to blow off.  The intelligent system will change the 
motor speed to maximise the flow of water when hot, due to the lack of water flow through the 
motor. 

•  The motor and electrical components are totally encapsulated in epoxy resin, ensuring safe 

operation under water.

•  The pump has a robust bearing and shaft design so no oil/grease lubrication is required.
•  PondMAX Filtration & Waterfall Pumps are heavy-duty reated and design for continuous use. 

•  Any damage to the equipment or unmerited 

operation will bring dangers to the surrounding 
precincts. If there is any damage of the 
equipment, it must not be used and should be 
placed out of reach of children.

•  For your own safety, disconnect the pump from 

the power supply before any maintenance of 
any equipment is performed.  This includes 
maintenance to the tank or pondliner.  Always 
unplug the pump from the power supply when 
not in use.

•  Never pull the cable to disconnect the plug 

from the power supply - Grasp the plug and 
pull to disconnect.

•  If required, have a qualified electrician install a 

weatherproof power supply point near to the 
pond or water-feature (within the cable length 
of the appliance).

•  Be sure the equipment is submerged 

completely in the water. The depth should not 
be greater than 6ft.

•  Do not operate the pump if the appliance or 

any components of the system, such as the 
power cable, have been damaged. Check 
appliance for defects regularly.

•  Always use a properly grounded power supply 

that is connected to a GFCI with a rated 
residual operating current not exceeding 30mA.

•  To avoid an electric shock, do not attach the 

plug to the power supply socket with wet 
hands. On installation, the drip loop method 
should be used to prevent water from traveling 
down the cable and onto the plug or power 
supply. If the plug does get wet, do not unplug 
the cable. Immediately disconnect the circuit 
breaker that supplies power to the power 
supply point. Then unplug and examine the 
plug, and power supply point, for presence of 
water. If the power point has become wet, you 
should consult an electrician before using the 
power point again.

•  Do not cut the cable as this will result in 

voiding your warranty.

•  Do not install or store the appliance where 

it will be exposed to extreme hot or cold 
temperatures. Do not use in water above 95°F 
(35°C).

•  Care should be taken to arrange the power 

cable so that it cannot be accidentally tripped 
over or pulled.

•  Do not attempt to repair the electrical 

appliance yourself. Return to an authorized 
service centre or place of purchase if a fault 
occurs, (regular maintenance is not considered 
repair and is required by the user)

IMPORTANT SAFEGUARDS

Please read the operating instructions and familiarise yourself with the equipment before placing 
it into service. Correct and safe use of the system requires strict compliance with the safety 
instructions.

For safety reasons persons less than 16 years of age or that are not familiar with these instructions 
should not use this equipment.

PMAX PX20000_30000 Pumps Instructions.indd   3

26/9/19   11:22 am

Содержание PX4500

Страница 1: ...HIGH FLOW WATERFALL PUMP INSTRUCTION MANUAL US 888 868 1185 CAN 888 855 4551 DATE AUG 2019 v1 0US MODEL PX4500 PX4500A PMAX PX20000_30000 Pumps Instructions indd 1 26 9 19 11 22 am ...

Страница 2: ... application Open Vane Impeller Handles particles size up to 6mm of sediment Long Life Impeller Ceramic shaft is wear resistant and self lubricated by water Energy Efficient Exceptional low power consumption to water flow ratio Eco Friendly Exceptional low dB noise rating with low mechanical vibration Compatibility Suitable for fresh water submersible applications DESCRIPTION PX4500 PX4500A MAX WA...

Страница 3: ...length of the appliance Be sure the equipment is submerged completely in the water The depth should not be greater than 6ft Do not operate the pump if the appliance or any components of the system such as the power cable have been damaged Check appliance for defects regularly Always use a properly grounded power supply that is connected to a GFCI with a rated residual operating current not exceedi...

Страница 4: ...specifications at the beginning of this manual Larger tubing size is always recommended for high flow rate pumps Select the hose tail required for your tubing size and evaluate which step on the hosetail will be used If you are using 2 inch hose and you are connecting it to a 1 5 2 hosetail remember to saw off the smaller size connection I E 1 5 step Otherwise it will create an unnecessary restric...

Страница 5: ... of any blockage This is a colling channel for the motor 1 Clean the housing and pump with a suitable brush taking care to clean off sludge algae and debris 2 To maintain the impeller of the pump remove the impeller cover screws to separate the impeller cover from the pump motor body 3 Lift out the impeller assembly Take care not to break ceramic shaft The black disc behind the blades is part of t...

Страница 6: ...l The use of any other accessories or attachments might present a risk of injury to persons Only use the accessory or attachment for its stated purpose 6 5 4 3 1 2 7 8 1 Pump Base 2 Pump Body 3 Impeller Assembly 4 Impellor O Ring 5 Impellor Cover 6 Front Cage 7 Hose Tail 8 2 Pipe Connector PMAX PX20000_30000 Pumps Instructions indd 6 26 9 19 11 22 am ...

Страница 7: ...t underwater then plug in Refill if necessary Blocked impeller chamber or ceramic shaft is broken Clean the impeller Check for ware Replace if necessary Water Pump is noisy Blockage in pump Clear the blockage Impeller shaft worn out Replace impeller assembly Impellor broken Replace impeller assembly Water valve closed on the outlet Open the valve and allow water to flow Pump inlet is blocked Clear...

Страница 8: ...rranty Purchaser shall bear all shipping packing and insurance costs and all other costs excluding labor and parts necessary to effectuate repairs under this warranty This warranty is in lieu of all other express warranties which now or hereafter might otherwise arise with respect to this product Any and all limited warranties including the warranties of merchantability and fitness for particular ...