background image

PLEASE CALL 1-888-755-6750 BEFORE RETURNING TO THE STORE. 

                      WWW.THEPONDBOSS.NET

 

LIMITED WARRANTY 

 
All pumps and electrical products are warranted to the user against defective material and workmanship, under 
normal working conditions.  This warranty period begins on the date of purchase by the original purchaser.   
 
Unless otherwise specified all pond boss® electrical products are warranted to the user against defective 
material and workmanship, under normal working conditions for 1 year from the date of purchase.   

 

Pond and Waterfall pumps are warranted for 3 years.   

 

All pond boss® liners are warranted to the user against defective workmanship, under normal working 
conditions for 20 years from the date of purchase.   

 

All other pond boss® products are warranted to the user against defective material and workmanship, 
under normal working conditions for 90 days.   

 

Application 

Warranty covers only properly installed and maintained units.  Any damage to the cord or modification to the unit 
will invalidate the warranty.  Pump warranty is limited to applications pumping fresh water in a pond or fountain 
only.  Other liquid applications or extreme temperature uses must be approved in writing by the manufacturer.  
Receipt and product date code are required for warranty claims. 
 

Warranty Claim 

Warranty claims must be made by calling customer service (at 1-888-755-6750).  If the item is determined 
to be defective, you will be given authorization to return the defective part(s), freight pre-paid, along with proof of 
purchase. 
 

 

Disposition 

The manufacturer will make a good faith effort for prompt disposition regarding all warranty claims.  Returned 
product will be inspected to determine cause of failure before warranty is applied.  Warranty does not cover any 
costs associated with the shipping, handling, installation or removal of products or parts subject to this warranty.  
For products damaged in transit, a claim should be filed with the carrier. 
 

Disclaimer 

Any oral statements made about the product by the seller, the manufacturer, the representatives, or any other 
parties do not constitute warranties, should not be relied upon by the user, and are not part of the contract for 
sale.  The seller’s and manufacturer’s only obligation, and buyer’s only remedy shall be for the manufacturer to 
either replace and/or repair at the manufacturer’s sole discretion, the product as described above.  Neither seller 
nor the manufacturer shall be liable for injury, loss or damages for lost profits, lost sales, injury to person or 
property, or any other incidental or consequential loss arising from any cause whatsoever, no matter whether 
based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy 
shall be available to them. Before using, the buyer and user shall determine the suitability of the product for the 
intended use, and assume all risk and liability whatsoever in connection therewith.  The warranty and remedy 
described in this limited warranty is an exclusive warranty and remedy in lieu of any other warranty or remedy 
expressed or implied.  All other warranties and remedies are hereby expressly excluded, including but not 
limited to any implied warranty of merchantability of fitness for any particular purpose.  This warranty gives the 
buyer and user specific legal rights, and buyer and user may also have other rights which vary from state to 
state.  Some states do not allow exclusions or limitations of incidental or consequential damages, so the above 
limitations or exclusions may not apply to you. 
 

REMINDER 

CALL 1-888-755-6750 

BEFORE RETURNING TO STORE. 

 

Содержание PW1300UV

Страница 1: ...mp has not been investigated for use in swimming pools or marine areas CAUTION This pump has been evaluated for use with fresh water only Use a proper power source as indicated on the pump label Keep the cord away from high temperatures or other heat sources Do not pump heated liquids Do not let the pump run dry Pump must be completely submerged for proper operation and cooling Operate in fresh wa...

Страница 2: ...ent Compare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble install or operate the product Contact customer service for replacement parts Estimated Assembly Time 5 minutes Tools Required for Assembly Philipshead screwdriver OPERATION INSTRUCTIONS 1 Connect the adapter to the pump by inserting into the pump discharge and twisting clock...

Страница 3: ...indicates whether or not the UV light is on or off Fig 5 Fig 5 6 Adjust the flow control to the preferred setting Fig 6 Fig 6 MAINTENANCE PROCEDURE In order to insure optimal operation of the UV pump the following procedures should be performed periodically When the performance of the pump is reduced it is an indication that cleaning of the unit is needed 1 Unplug pump remove from pond Fig 7 Fig 7...

Страница 4: ...ug the pump and proceed to step 3 Fig 8 3 Remove the front cover from the pump Fig 9 Fig 9 4 Remove the impeller cover to expose the impeller assembly Remove the impeller assembly by gently pulling on the impeller blades Use a soft cloth or brush to clean the impeller assembly and inside of the impeller housing Fig 10 Fig 10 5 Remove the locking screw which is located on the bottom of the pump Fig...

Страница 5: ...ikely event the UV bulb needs replacing remove glass tube by turning the glass tube assembly counterclockwise and pulling away from the lamp base Gently the pull bulb straight apart from the bulb socket and insert the replacement bulb in the reverse manner Fig 14 Fig 14 9 Clean the exterior of the UV glass tube with warm soapy water Fig 15 Fig 15 10 Reassemble all of the components Fig 16 Fig 16 C...

Страница 6: ...ke sure the power cord is plugged in the pump is getting power and the pump is fully submerged Check the pump outlet and any tubing fountains spitters etc for kinks or obstructions Remove the inlet screen and or pump cover and impeller cover to expose the impeller Turn the impeller to ensure that it is not broken or jammed Also check the ceramic shaft to make sure that it is not broken If the perf...

Страница 7: ...E FLOW RATES LIFT FEET 12 476 GPH 11 560 GPH 10 630 GPH 9 710 GPH 8 793 GPH 7 850 GPH 6 910 GPH 5 970 GPH 4 1 040 GPH 3 1 100 GPH 2 1 170 GPH 1 1 268 GPH 0 1 375 GPH PW1300UV Printed in China Part Description B 1 in adapter with flow control C Pump barrier bag D Front cover E Impeller cover F Impeller assembly G Ceramic shaft H Shaft support I Rear cover J Top cover K Screw L Light cover M Flow ch...

Страница 8: ... warranty is applied Warranty does not cover any costs associated with the shipping handling installation or removal of products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral statements made about the product by the seller the manufacturer the representatives or any other parties do not constitute warranties should no...

Отзывы: