Pompetravaini TCTM Скачать руководство пользователя страница 7

Disassembly & assembly instructions single stage centrifugal pumps series TCHM & TCTM 

7

Tab. 1

 

BEARINGS TYPE 

RADIAL SEAL RINGS TYPE for SHAFT

Motor frame 

Motor frame 

 

PUMP 

MODEL 

80 
90 

100 
112 

132 

160 
180 

200 

80 
90 

100 
112 

132 

160 
180 

200 

* MECHANICAL

SEAL 

Ø (mm) 

25-125 
25-160 
25-200 

32-125 

 

32-160 

 

32-200 

 

40-125 

 

40-160 

 

40-200 

 

50-125 

 

50-160 

 

G

roup 1 

50-200 

 

6208.2RS 

(40x80x18) 

6011.2RS 

(55x90x18) 

--- 

AS40527 

(40x52x7) 

AS55708 

(55x70x8) 

--- 30 

32-250 

40-250 

 

40-315 

50-250 

 

65-125 

65-160 

 

65-200 

 

65-250 

 

80-160 

 

80-200 

 

80-250 

 

G

roup 2 

100-200 

 

6011.2RS 

(55x90x18) 

6214.2RS 

(70x

125x

24)

 

AS55708 

(55x70x8) 

AS709010 

(70x

90x

10)

 

45 

100-250 

125-250 

 

--- 

6214.2RS 

(70x125x24) 

--- 

AS709010 

(70x90x10) 

G

roup 3 

150-250 --- 

6214.2RS 

(70x125x24) 

--- 

AS709010 

(70x90x10) 

55 

 

Available 

on 

TCTM 

design 

         * 

According 

to 

DIN 

24960 

standards 

 
Tab. 2 

DIAMETRAL CLEARANCE in mm 

BETWEEN IMPELLER NECK AND WEAR RING

 

NOMINAL DIMENSIONS 

OF WEAR RINGS 

DESIGN 

PUMP 

MODEL 

A B H 

F - RA

 

A3

 

IMPELLER 

MINIMUM 

BALL SIZE

mm 

25-125 

72 

84 

13 

0,33 - 0,48 

0,43 - 0,58 

25-160 

72 

84 

13 

0,33 - 0,48 

0,43 - 0,58 

25-200 

72 

84 

13 

0,33 - 0,48 

0,43 - 0,58 

32-125 

72 

84 

13 

0,33 - 0,48 

0,43 - 0,58 

32-160 

72 

84 

13 

0,33 - 0,48 

0,43 - 0,58 

32-200 

72 

84 

13 

0,33 - 0,48 

0,43 - 0,58 

32-250 

85 

97 

13 

0,44 - 0,59 

0,74 - 0,89 

40-125 

85 

97 

13 

0,34 - 0,49 

0,44 - 0,59 

10 

40-160 

85 

97 

13 

0,34 - 0,49 

0,44 - 0,59 

7,5 

40-200 

85 

97 

13 

0,34 - 0,49 

0,44 - 0,59 

40-250 

95 

110 

16 

0,44 - 0,59 

0,74 - 0,89 

6,5 

40-315 

95 

110 

16 

0,44 - 0,59 

0,74 - 0,89 

50-125 

95 

110 

16 

0,34 - 0,49 

0,44 - 0,59 

16 

50-160 

95 

110 

16 

0,34 - 0,49 

0,44 - 0,59 

13 

50-200 

95 

110 

16 

0,34 - 0,49 

0,44 - 0,59 

50-250 

105 

120 

16 

0,44 - 0,59 

0,74 - 0,89 

50-315 

105 

120 

16 

0,44 - 0,59 

0,74 - 0,89 

7,5 

65-125 

105 

120 

16 

0,44 - 0,59 

0,74 - 0,89 

20,3 

65-160 

120 

135 

16 

0,44 - 0,59 

0,74 - 0,89 

18 

65-200 

120 

135 

16 

0,44 - 0,59 

0,74 - 0,89 

14 

65-250 

120 

135 

16 

0,44 - 0,59 

0,74 - 0,89 

12 

80-160 

135 

150 

16 

0,44 - 0,61 

0,74 - 0,91 

25 

80-200 

135 

150 

16 

0,44 - 0,61 

0,74 - 0,91 

21 

80-250 

135 

150 

16 

0,44 - 0,61 

0,74 - 0,91 

15 

100-200 

150 

170 

18 

0,44 - 0,61 

0,74 - 0,91 

27 

100-250 

150 

170 

18 

0,44 - 0,61 

0,84 - 1,01 

18 

125-250 

180 

200 

20 

0,44 - 0,61 

0,84 - 1,01 

30 

150-250 

215 

235 

20 

0,45 - 0,62 

0,85 - 1,02 

 

48 

 

H

ØA

ØB

 

Содержание TCTM

Страница 1: ... Rev 2 0_10 2010 DISASSEMBLY ASSEMBLY INSTRUCTIONS SINGLE STAGE CENTRIFUGAL PUMPS TCHM TCTM ...

Страница 2: ...ifficulties in repairing the pump it is recommended to send the pump for repair to POMPETRAVAINI or the local authorised representative Pump repairs and or service carried out by customer or unauthorised personnel are not guaranteed by POMPETRAVAINI or by its subsidiaries Note Pump parts list identify all pump components by item number VDMA in connection with the sectional drawings All drawings ar...

Страница 3: ...be in the pump assembly Remove the nuts from studs VDMA 902 1 remove casing cover VDMA 161 from lantern flange VDMA 341 Particular care should be given when removing the mechanical seal components from the pump mechanical seals are fragile and may easily get damaged when mishandled Remove the stationary mechanical seal face from the casing cover replace if necessary For complete pump disassembly p...

Страница 4: ... of the stationary seal face Seal must be suitable for clockwise rotation unless it is a bi directional type Slide and locate the seal locating ring in the original location which had been marked or at the measured location then tighten the two set screws To prevent seal damages and breakdowns it is recommended not to use excessive force when fitting the seals their components can be fragile ONLY ...

Страница 5: ...902 2 183 902 1 904 320 433 2 932 932 1 542 901 1 341 901 210 Fig 1 Pump series TCHM gr 1 and 2 design 1 C Single mechanical seal and motor frame 80 and 90 421 925 940 2 230 161 102 903 3 562 400 1 903 1 485 902 2 932 1 902 1 904 320 433 2 932 183 542 901 1 341 901 210 110 Fig 2 Pump series TCTM gr 1 and 2 design 1 C Single mechanical seal and motor frame 80 and 90 ...

Страница 6: ... 542 Mechanical seal bush 183 Support foot 562 Pin 210 Shaft 901 Screw 230 Impeller 902 Stud 320 Ball bearing 903 Plug 341 Lantern 904 Grub screw 400 1 Gasket 925 Impeller locking nut 421 Radial seal ring 932 Circlip 433 2 Mechanical seal 940 Key 6 ENGINEERING TABLES Fig 3 Torque values for various bolt sizes Torque values Nm 300 200 100 20 50 15 30 40 60 70 80 150 4 6 8 10 12 14 16 18 20 22 24 26...

Страница 7: ...72 84 13 0 33 0 48 0 43 0 58 6 25 160 72 84 13 0 33 0 48 0 43 0 58 6 25 200 72 84 13 0 33 0 48 0 43 0 58 5 32 125 72 84 13 0 33 0 48 0 43 0 58 6 32 160 72 84 13 0 33 0 48 0 43 0 58 5 32 200 72 84 13 0 33 0 48 0 43 0 58 5 32 250 85 97 13 0 44 0 59 0 74 0 89 6 40 125 85 97 13 0 34 0 49 0 44 0 59 10 40 160 85 97 13 0 34 0 49 0 44 0 59 7 5 40 200 85 97 13 0 34 0 49 0 44 0 59 6 40 250 95 110 16 0 44 0 ...

Страница 8: ...at 1 m Pressure dB A Power dB A INSTALLATION SERVICE Inside Outside Continuous Intermittent Explosive area MOTOR type Frame No Poles No Revolutions RPM Absorbed power Amp Installed Power kW HP Frequency Hz Supply Volt Enclosure IP Insulation class Absorbed Power kW HP COMMENTS NA5 SM TCHM GB00 PRINTED IN ITALY Smontaggio TCHM TCTM Inglese POMPETRAVAINI S continuing research results in product impr...

Отзывы: