4’’ SUBMERSIBLE PUMP  INSTALLATION INSTRUCTIONS  

 

IMPORTANT: 

Read carefully this manual before installing or operating the pump. 

 

CAUTION: 



Review instructions before operating the pump. 



Electrical installation shall be in accordance with the National Electrical Code, and all applicable local codes and ordinances. 



This submersible pump may develop very high pressure,  therefore it is an obligation to install a relief valve on the 

tank to avoid possible danger of the tank bursting that can cause property damage and/or personal injury and/or 

death. 

 

WARNING  -  RISK OF ELECTRICAL SHOCK: 



Have a qualified electrician provide electrical power to motor. 



Ensure lead and ground wires are properly waterproof and securely connected. 



Always disconnect power before servicing. 



This pump is built to be used in a water well.  Never use it in swimming pools. 



Never test a pump or use a pump outside a well without grounding it. 

 

BEFORE INSTALLATION

 

Above all, it is necessary to clean up your well.  You should remove all foreign particles, like sand, that can damage the pump.  

This step must generally be done by your well driller.  Your submersible pump must be installed at a minimum of 15 feet (5 m) from 

the bottom of your well in order to prevent aspiration of sand by the pump. 

 

WARNING:  To prevent dropping the pump in the well, it is recommended that a 1/4" minimum diameter nylon safety rope 

(according to the depth) be attached to the pump and up at top of the well.  On the discharge head of the pump, a ring allows the 

fastening of the rope and, at the top of the well, the rope can be attached to the hook supplied with the well cap (ex.: CVA-600).  It 

is important that there is no any tension on nylon safety rope. 

 

INSTALLATION 

SPLICING CONNECTORS, protected by heat-shrink tubing. 

It is very important to use only submersible cable. 

1)  Remove 3/8" (9.5 mm) insulation from ends of motor leads and drop cable wires. 

2)  Slide plastic heat shrink tubing over motor leads.  

3)  Match colors and lengths of drop cable to colors and lengths of motor leads. 

4)  Insert cable and motor wires  into butt connectors (Fig. 1).  Crimp connectors and weld with tin (Fig. 2).  Pull leads to check if 

the connections are secure. 

5)  Center heat-shrink tubing over butt connectors (Fig. 3) and heat  with a torch (a match or lighter will not supply enough heat). 

IMPORTANT:  

Keep torch moving, because too much concentrated heat may damage tubing. 

 

PUMP INSTALLATION

 

1)  Use a good quality pipe (ex.: polyethylene pipe) that will resist to high pressure produced by the system. 

2)  Take care to cut the pipe at the exact length that you need.  It is important to remember that the pump must be installed at a 

minimum of 15 feet (5 m) from the bottom of the well. 

3)  All pumps arrive with a check valve.  For installation over 200 feet (60 m), install an extra check valve at the tank entrance  and 

at each 100 feet (30 m). 

4)  It is important to install a torque arrestor 1 foot (30 cm) above the pump to reduce torque strain produced by motor starting and 

stopping. 

5)  With the pipe installed, the pump can now be taken down into the well. 

6)  Fasten the electrical cable on the pipe with clamps or tape at every 10 feet (3 m) to avoid  damages.  At the first fastener, you 

must give a little slack to the cable to get a safe installation.  Take care not to scrape the submersible cable against well casing 

when you lower the pump into the well. 

7)  Use an ohmmeter to make insulation and continuity checks on the cable once the pump is installed.  It locates any default in 

the electrical cable. 

8)  Don't forget to fasten the nylon rope to prevent losing of pump.  (Don't put tension on the cable) 

 

CONTROL CENTER INSTALLATION

 

There are many ways to arrange a submersible pump control center. 

1)  Do a good choice of tank adapted to your installation.  The dealer will inform you. 

2)  At the entrance of the tank, many controls and measuring displays are needed for a good pump operation.  These controls are 

a pressure gauge , a relief valve and a pressure switch.  

ADVICE: 

Teflon paste is recommended for all threaded joints. 

 

ELECTRICAL INSTALLATION

 

1)  It is recommended that a qualified electrician be employed to connect the pump.  All electrical installations shall be in 

accordance with the National Electrical Code, and all applicable local codes and ordinances. 

2)  A pump with a 2 wire motor does not need control box.  All electrical components are incorporated in the motor. 

3)  A pump with a 3 wire single phase motor needs a control box that includes a relay and a capacitor.  The control box is always 

filled by the manufacturer.  Do the connecting to the control box as showed in wiring diagram, to avoid damage to the motor. 

4)  Respect the length of electrical cable recommended by the motor manufacturer.  If you don't respect this, it's sure that the 

warranty will null.  

 

INSTALLATION IN LAKE OR RIVER

 

In all cases, the pump must be supported at 15 degree slant to assure proper bearings lubrification whether the pump be placed 

near the slope or in the bottom.  Shield the pump from direct physical contact.  Protect and screen the pump intake to prevent 

blockage by leaves and weeds, but remember the need for an adequate flow over the motor for cooling purposes.  A flow inducers 

sleeve must be installed over the motor and a the entry of the pump. (fig. 4)  In addition, protect the entire underwater installation 

from water currents, ice, etc...  

NOTE: 

A submersible pump is usually isolated at the bottom of a well, where electrical leakage from the motor and cable presents 

no hazard to human life.  This natural protection is lost when you install it in a lake, pond or river (there is no way to stop people 

from entering or touching surrounding water).  Take precaution in that sense. 

Typical submersible installation with diaphragm tank (2 wire motor)

Installation submersible typique avec réservoir préchargé  (moteur 2 fils) 

Instalación sumergible típica con tanque precargado (motor de 2 hilos) 

Gate valve
Soupape

Llave de paso

Electrical disconnect

Sélectionneur électrique

Selector eléctrico

Pressure gauge
Manomètre
Manómetro

Pressure switch

Interrupteur de pression

Interruptor de presión

Relief valve

Soupape de sûreté
Válvula de alivio

Pump
Pompe
Bomba

Safety rope

Câble de sûreté

Cable de alivio

Electrical cable

Câble électrique
Cable eléctrico

Tape cable to pipe

Attaches

Abrazadera

Pitless adapter

Coulisseau adapteur
Cursor de ajuste

Check valve
Soupape de retenue
Válvula check

Torque arrestor
Amortisseur
Amortiguador

Electrical entry

Entrée électrique

Alimentación eléctrica

Typical submersible installation with galvanized tank (3 wire motor)

Installation submersible typique avec réservoir galvanisé  (moteur 3 fils) 

Instalación sumergible típica con tanque galvanizado (motor de 3 hilos) 

Valve
Soupape

Llave de paso

Electrical disconnect

Sélectionneur électrique

Selector eléctrico

Relief valve

Soupape de sûreté
Válvula de alivio

Pump
Pompe
Bomba

Safety rope

Câble de sûreté

Cable de alivio

Electrical cable

Câble électrique
Cable eléctrico

Tape cable to pipe

Attache

Abrazadera

Pitless adapter

Coulisseur adapteur
Cursor de ajuste

Check valve
(with snifter valve)
Soupape de retenue
(avec reniflard)
Válvula check
(con pivote)

Bleeder orifice

Purgeur

Purgador

Pressure gauge
Manomètre
Manómetro

Air volume control

Contrôle de volume d'air
Control del volumen de aire

Pressure switch

Interrupteur de pression

Interruptor de presión

Control box

Boîte de contrôle

Caja de control

Torque arrestor
Amortisseur
Amortiguador

Electrical entry

Entrée électrique

Alimentación eléctrica

Содержание FLS

Страница 1: ...5 À 5 CV MonoDrive SubDrive 75 150 300 PÉRIODE DE LA GARANTIE PRODUITS LIMITED WARRANTY SUBMERSIBLE PUMPS POMPCO s consumer warranty per product group and warranty period All submersibles mentioned in the above column are guarantied from any manufacturer s defaults or not performing as well as it should be even when they are used and maintained according to Pompco s written instructions All defect...

Страница 2: ... to arrange a submersible pump control center 1 Do a good choice of tank adapted to your installation The dealer will inform you 2 At the entrance of the tank many controls and measuring displays are needed for a good pump operation These controls are a pressure gauge a relief valve and a pressure switch ADVICE Teflon paste is recommended for all threaded joints ELECTRICAL INSTALLATION 1 It is rec...

Страница 3: ...r 3 8 po 9 5 mm 2 Glisser un tube thermorétractable en plastique sur les fils du moteur 3 Assortir les couleurs et les longueurs des fils du câble de jonction avec celles des fils du moteur 4 Introduire bout à bout les fils assortis du câble de jonction et du moteur dans les connecteurs Fig 1 Écraser les connecteurs sur les fils et les souder à l étain Fig 2 Tirer les conducteurs pour s assurer qu...

Страница 4: ...pozo 3 Cada bomba está dotada de una válvula check Para instalaciones mayores de 200 pies 60m instale una válvula check complementaria en la boca del depósito cada 100 pies 30m 4 Es importante instalar un amortiguador TA 48 aproximadamente de un pie 30cm arriba de la bomba para limitar los esfuerzos de acoplamiento en el encendido y apagado del motor 5 Una vez instalado el tubo se puede bajar la b...

Отзывы: