![POMCube iCAN Mini 3500 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/pomcube/ican-mini-3500/ican-mini-3500_user-manual_1578666027.webp)
26
4
Input
undervoltage
protection of
Utility
When utility voltage is lower than 100V, the utility charging will be stopped, but the
derated by-pass output can be achieved.
5
Overvoltage
protection for
battery
When the battery voltage reaches the voltage point of overvoltage disconnection, the
PV and utility will be automatically stopped charging the battery, preventing the
battery from being damaged due to overcharge.
6
Low-voltage
protection for
battery
When the battery voltage reaches the voltage point of low-voltage disconnection,
discharging the battery will be automatically stopped, preventing the battery from
being damaged due to over-discharge.
7
Short circuit
protection for
load output
When short-circuit fault of the load output occurs, the output AC voltage will be
immediately turned off and output will be recovered again in 1 minute. If output is
recovered for 3 times and short-circuit fault of the load output still exist, the short-circuit
fault of the load must be eliminated firstly, then it can be turned on manually to restore the
normal output.
8
Over-
temperature
protection for
radiator
When the internal temperature of the iCAN Mini is too high, charge and discharge will
be stopped; when the temperature returns to normal, charge and discharge will be
recovered.
9
Overload
protection
When overload protection occurs, output will be recovered again in 3 minutes, if
continuous overload appears 5 times, output will be turned off until the power supply
for the machine is restored. For the specific overload level and duration, please refer to
the technical parameter table of the manual.
6.2 Fault code explanation
Fault code table for inverter with controller
Fault code
Fault name
Whether it affects
the output
Remarks
【
01
】
BatVoltLow
Y
Low-voltage alarm
【
02
】
-
-
-
【
03
】
BatOpen
Y
Open battery alarm
【
04
】
BatLowEod
Y
Stopping discharging
alarm due to low-
voltage of battery
【
05
】
BatOverCurr
Y
Battery overcurrent
protection
【
06
】
BatOverVolt
Y
Charging overvoltage
protection
【
07
】
BusOverVoltHw
Y
Overvoltage hardware
protection for bus
【
08
】
BusOverVoltSw
Y
Overvoltage software
protection for bus