187
Appendix
Appendix
Global Management System User’s Guide
iPower Admin Setup Menu
Admin Tools :: ISDN ::
IMUX Setup
IMUX Setup
iPower Field
Type
Meaning
IMUX type
Pull Down
menu
None
The external network device does not use rate
codes, or users prefer to dial the code themselves.
DICA OASIS
The system is attached to a DICA OASIS IMUX. The
system will automatically generate rate codes for
outgoing calls based on this IMUX type.
Lucent Multiband
The system is attached to a Lucent Multiband IMUX.
The system will automatically generate rate codes
for outgoing calls based on this IMUX type.
Other
The system is attached to an IMUX that uses rate
codes, but not to one of the known types listed
above. Please fill in the table so the system can
generate rate codes for outgoing calls.
IMUX Call Mode
Pull Down
menu
Dialed
This is the default mode. The system can place an
outgoing call by dialing a number. It can also receive
incoming calls.
DCE Signaled
(non-dialed)
The network does not need a phone number to
route a call. Typically, the network is pre-configured
to a specific destination. V.35/RS-449 control leads
signal the start and end of a call.
DCE Dedicated
(non-dialed)
The network provides a permanent connection.
The V.35/RS-449 control leads are constant and
do not signal the start or end of a call. Instead, the
system uses framing patterns in the transmitted and
received data to signal the start and end of a call.
Maximum call rate
Pull down menu Call rate supported by IMUX box.
IMUX Code setup
Table
Please refer to the iPower administrator user guide.