background image

 

Prepare for Installing RealPresence Collaboration Server (RMX) 1800

Polycom, Inc. 

18

 

 

 

Install the heaviest components on the bottom of the rack first, and then work up.

Allow the power supply units to cool before touching them.

Installation Precautions

When handling electronic components, standard anti-static precautions must be observed:

Wear a grounding strap

Keep components in anti-static bags, when not installed in the RealPresence Collaboration Server 
(RMX) 1800.

The number of power units (maximum two, default one) varies by your product package.

The following precautions should be followed with regards to installation of the RealPresence Collaboration

Server (RMX) 1800:

Use a regulating uninterruptable power supply (UPS) to protect the RealPresence Collaboration 
Server (RMX) 1800 from power surges and voltage spikes, and to keep your MCU operating in case 
of a power failure.

Place the RealPresence Collaboration Server (RMX) 1800 on a hard, flat surface such as a desktop, 
or mount it on a 19” rack.

The airflow of the RealPresence Collaboration Server (RMX) 1800 is from front to back. Be sure that 
the areas in the front and rear side of the system are clear for proper ventilation.

Unpack the RealPresence Collaboration Server (RMX) 
1800

Perform the following steps to unpack and lift the RealPresence Collaboration Server (RMX) 1800.

To unpack the RealPresence Collaboration Server (RMX) 1800:

1

When you receive the RealPresence Collaboration Server (RMX) 1800 packing case, inspect the 
equipment for damage and verify that the components match the packing slip.

2

Open the top cover of the packing case.

Boxes are placed on the top Stratocell

®

 and contain one AC power cable, two ethernet cables, one 

USB key, one DB-9 Serial cable and one printed ISDN license.

Make sure that the box contains all the required parts.

Warning: Warranty void if the seal is broken

The RealPresence Collaboration Server (RMX) 1800 is a sealed system, so breaking the seal and

opening the chassis

 voids the warranty.

Содержание Collaboration Server (RMX) 1800

Страница 1: ...Version 8 5 December 2014 3275 69957 004 B Hardware Guide RealPresence Collaboration Server RMX 1800...

Страница 2: ...stribution date of the applicable product or software at a charge not greater than the cost to Polycom of shipping or distributing the software to you To receive software information as well as the op...

Страница 3: ...s a listing of batteries that could be present in the product Description Internal CMOS battery Type CR2032 Lithium Coin Cell Weight 3 3g Batteries used in this product are in compliance with EU Batte...

Страница 4: ...y be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you be...

Страница 5: ...ce Collaboration Server RMX 1800 18 Install the RealPresence Collaboration Server RMX 1800 20 Mount the RealPresence Collaboration Server RMX 1800 on a Shelf 20 Connect the RealPresence Collaboration...

Страница 6: ...Table of Content Polycom Inc 6 Korea 32...

Страница 7: ...1080p60 high definition video conferencing Telecommunication grade high availability and on line upgrading Easy integration of conference elements into external network management Enhanced Continuous...

Страница 8: ...Siren LPR Video H 261 H 263 H 263 H 264 H 264 High Profile H 264 SVC Network Ports Signaling H 323 SIP ISDN LAN LAN 1 LAN 2 ISDN PRI1 PRI 2 PRI 3 PRI 4 each can work as either an E1 port or T1 port P...

Страница 9: ...number of conferences 200 Maximum number of Meeting Rooms 1000 Maximum number of Entry Queues 40 Maximum number of Profiles 80 Maximum number of Conference Templates 400 Maximum number of SIP Factori...

Страница 10: ...Systems with Three DSP Cards in Non mixed Conferences Licenses AVC 1080p60 AVC 1080p30 AVC HD720p30 AVC SD AVC CIF Audio SVC 720p SVC 1080p 5 1 2 5 10 10 60 15 15 10 2 5 10 20 20 120 30 30 15 3 7 15...

Страница 11: ...5 0 24 0 48 1 00 2 00 2 00 12 00 3 00 3 00 30 0 23 0 50 1 00 2 00 2 00 10 00 3 00 3 00 35 0 23 0 49 1 00 2 00 2 00 8 57 3 00 3 00 40 0 25 0 50 1 00 2 00 2 00 7 50 3 00 3 00 45 0 24 0 49 1 00 2 00 2 00...

Страница 12: ...0p30 AVC HD720p30 AVC SD AVC CIF Audio SVC 720p SVC 1080p 5 1 2 5 10 10 60 15 15 10 2 5 10 20 20 120 30 30 15 3 7 15 30 30 180 45 45 20 5 10 20 40 40 240 60 60 25 6 12 25 50 50 300 75 75 30 7 15 30 60...

Страница 13: ...C 720p SVC 1080p 5 1 2 3 6 6 60 15 15 10 2 4 6 13 13 120 30 30 15 3 6 10 20 20 180 45 45 20 4 8 13 26 26 200 60 60 25 5 10 16 33 33 200 75 75 30 6 12 20 40 40 200 90 90 35 7 14 23 46 46 200 105 105 40...

Страница 14: ...30 1 30 10 00 3 00 3 00 25 0 20 0 40 0 64 1 32 1 32 8 00 3 00 3 00 30 0 20 0 40 0 67 1 33 1 33 6 67 3 00 3 00 35 0 20 0 40 0 66 1 31 1 31 5 71 3 00 3 00 40 0 20 0 40 0 65 1 33 1 33 5 00 3 00 3 00 45...

Страница 15: ...SVC to AVC in mixed conference Licenses AVC 1080p60 AVC 1080p30 AVC HD720p30 AVC SD AVC CIF Audio SVC 720p SVC 1080p 5 1 2 3 6 6 60 15 15 10 2 4 6 13 13 120 30 30 15 3 6 10 20 20 180 45 45 20 4 8 13...

Страница 16: ...bers of ISDN Voice or Video participants through E1 or T1 port in different bit rates ISDN Resource Capacities Line Rates Maximum Capacities 2M 200 4M 150 6M 100 Note ISDN on RMX 1800 with three DSP c...

Страница 17: ...cted only to a power outlet that has a protective ground contact Ensure that the power cord is easily accessible from the back of the system at all times Place the equipment in a well ventilated area...

Страница 18: ...lPresence Collaboration Server RMX 1800 on a hard flat surface such as a desktop or mount it on a 19 rack The airflow of the RealPresence Collaboration Server RMX 1800 is from front to back Be sure th...

Страница 19: ...Collaboration Server RMX 1800 Polycom Inc 19 2 Note Write down the serial number Write down the Collaboration Server serial number from the sticker on the back of the unit It will be needed for produc...

Страница 20: ...e Collaboration Server RMX 1800 on a shelf To mount the system on a shelf 1 Install the shelf supplied by the rack manufacturer in the rack 2 Mount the RealPresence Collaboration Server RMX 1800 on th...

Страница 21: ...utlines the way to connect the cables to the RealPresence Collaboration Server RMX 1800 To connect the cables to the RealPresence Collaboration Server RMX 1800 1 Connect the management network cable t...

Страница 22: ...Install the RealPresence Collaboration Server RMX 1800 Polycom Inc 22 RealPresence Collaboration Server RMX 1800 with three DSP cards rear panel...

Страница 23: ...Polycom Inc 23...

Страница 24: ...ry and applied during the power up sequence which may take up to five minutes When the system s configuration is completed including the Management and IP Network Services and if there are no system e...

Страница 25: ...oints connected to the meeting Flickering blue Diagnostic tests are running Blue Diagnostic tests are completed remove the USB key if applicable and restart the system 4 M S LED Blue System upgrade co...

Страница 26: ...Server RMX 1500 1800 2000 4000 Getting Started Guide 5 USB 2 For USB key connection 6 LAN 1 For management network connection when LAN redundancy is enabled LAN 1 is used for both management media and...

Страница 27: ...the power cable from the power unit The system beeps because it detects a power unit inserted without the power supply connected to it 2 Pull the power unit out using its handle The system stops beep...

Страница 28: ...pply or remove it from the system One of the power units is removed One of the power units fails Remove or replace the problem power unit Power units are hot swappable you don t need to restart the sy...

Страница 29: ...tected earth connection Only connect the system to surge protected power outlets Keep ventilation openings free of any obstructions If the system or any accessories are installed in an enclosed space...

Страница 30: ...e mise la terre Ne branchez ce syst me qu des prises prot g es contre les surtensions N obstruez pas les orifices de ventilation de l appareil Si le syst me ou des accessoires sont install s dans un e...

Страница 31: ...n the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may...

Страница 32: ...sposizioni pertinenti stabilite dalla direttiva 1999 5 CE slenska Icelandic H r me l sir Polycom UK Ltd yfir v a Polycom RMX er samr mi vi grunnkr fur og a rar kr fur sem ger ar eru tilskipun 1999 5 E...

Страница 33: ...olycom RMX sp a z kladn po iadavky a v etky pr slu n ustanovenia Smernice 1999 5 ES Suomi Finnish Polycom UK Ltd vakuuttaa t ten ett Polycom RMX tyyppinen laite on direktiivin 1999 5 EY oleellisten va...

Отзывы: