background image

LECOLOGICO AS807

40

E

E

N

N

G

G

L

L

I

I

S

S

H

H

cleaning of the water container 

(6)

; it may

also be used to clean the appliance’s hose
connections and the inside of tools.

NOTE: 

Do not use the brush for cleaning

the outside of the appliance

C

C

L

L

E

E

A

A

N

N

I

I

N

N

G

G

 

 

T

T

H

H

E

E

 

 

H

H

E

E

P

P

A

A

 

 

F

F

I

I

L

L

T

T

E

E

R

R

 

 

(

(

1

1

0

0

)

)

 

 

A

A

N

N

D

D

T

T

H

H

E

E

 

 

D

D

U

U

A

A

L

L

 

 

F

F

I

I

L

L

T

T

E

E

R

R

 

 

A

A

S

S

S

S

E

E

M

M

B

B

L

L

Y

Y

 

 

(

(

1

1

0

0

b

b

)

)

Proceed as follows to clean filters:

press the two levers on the filter cover 

(9a)

and pull off the filter cover 

(9) 

(fig.16);

pull on the “dual filter” 

(10b) 

to remove it

from its housing and then remove the micro-
filter and moisture protection filter that com-
pose it (fig.19).

rotate the filter retainer 

(10a) 

as shown in

fig.17 and remove the Hepa filter 

(10)

(fig.18);

rinse the filters in cold running water. Shake
them gently after washing to eliminate any
residual dirt and excess water.

when dry, put the filters back in the appliance,
performing the same operations in reverse
order.

NOTE: 

let the filters dry naturally, far away from

light and heat sources. You should wait 24
hours before reassembling filters in the appli-
ance.

Replace the filters if they are torn.

Filters should be cleaned every 4 months.

WARNING: 

do not clean filters with the brush,

as this could damage them, decreasing their fil-
tering capacity.
Do not use detergents, do not scrape filters, and
do not attempt to wash them in a dishwasher.

R

R

E

E

P

P

L

L

A

A

C

C

E

E

M

M

E

E

N

N

T

T

 

 

O

O

F

F

 

 

R

R

E

E

M

M

O

O

T

T

E

E

 

 

C

C

O

O

N

N

T

T

R

R

O

O

L

L

B

B

A

A

T

T

T

T

E

E

R

R

Y

Y

THE BATTERY IS NOT SUPPLIED WITH THE
PRODUCT.

In order to work, the remote control handle
needs to be powered by a 12V. type MN21 bat-
tery. The duration of the
battery depends on the frequency of use. If,
when pressing the buttons (

21

) or (

22

) on the

remote control, the
light (

23

) does not come on, replace the battery.

Take the remote control handle, press the lever
on the battery cover (

25

), pulling it towards the

keypad of the remote control.
Remove the small cover and replace the battery
taking care to match up the + and – signs with
those indicated. Replace the cover (

25

).

NOTE: 

in order to respect the environment, we

recommend that you dispose of the battery in
the specific collection bins.

T

T

R

R

O

O

U

U

B

B

L

L

E

E

S

S

H

H

O

O

O

O

T

T

I

I

N

N

G

G

The vacuum cleaner won’t start:

check that the appliance is plugged in

The vacuum cleaner goes off during use
and the four indicator lights come on:

a) there is too much liquid in the container.

Restore the correct level.

b) The selected power level is too high for the

type of surface you are cleaning.

In both cases, press the switch 

(1)

, unplug the

power cable and leave it unplugged for a few
seconds so that the safety device will be reset.

Suction power is decreased:

The nozzle, hose or tools may be blocked up, or
the Hepa filter may be dirty. Clean the Hepa fil-
ter and remove any obstructions from the hose.

Leakage of water when suctioning up liq-
uids:

The float may be blocked up. Clean the filter
assembly and make sure that the water level in
the container is correct.

The remote control does not work

Battery probably flat. Check the charge of the
battery and if necessary replace it..

LECOLOGICO AS807 M0S08537 1O09 8 LINGUE:Layout 1

30/09/2008

14.39

Pagina 40

Содержание LECOLOGICO AS807

Страница 1: ......

Страница 2: ...9 B Z E H F G C C1 L D1 D A A1 4 17 15 12 6 5 3 14 1 2 8 13 18 11 19 P1 P M 17 W 17b 17a 17c 6 16 O N Lecologico AS807 M0S08537 Edizione 1O09 Fig 12b B1 I 22 21 20 23 24 25...

Страница 3: ...2 Fig 3 Fig 4 Fig 5 Fig 8 Fig 11 Fig 7 Fig 6 Fig 12a Fig 13 Fig 1 Fig 14 Fig 15 Fig 16 Fig 17 Fig 9 Fig 10 Fig 18 Fig 19 Fig 20 Fig 21 7 9 9a 10 Fig 22 Fig 23 Fig 24 C L D 4 1 15 Fig 12 Fig 12b Fig 1...

Страница 4: ...irt preventing all contact with dust and avoiding dispersal of dust back into the air What is the HEPA filter Lecologico has a special extra powerful washable HEPA filter previously used only in profe...

Страница 5: ...eplace the power supply cable please refer to the nearest Polti autho rised service centre since the use of a spe cial tool is necessary Never touch the appliance with wet hands or feet with the cable...

Страница 6: ...rived from any use of Lecologico which is not in conformity with the instruc tions contained in this booklet A AT TT TE EN NT TI IO ON N Directive 2002 96 EC Waste Electrical and Electronic Equipment...

Страница 7: ...tton is pressed the power of the motor will decrease and the light indicator will go out To restore the appliance to the pause posi tion hold down button 20 Note so that the remote control operates in...

Страница 8: ...ic tube A The tube is about 60 cm long when closed 1 m when extended to its greatest length To increase or decrease length press the catch positioned as shown in fig 6 and extend or reduce length as d...

Страница 9: ...is useful for preventing allergies as the mechanical action of the roller with bristles vacuums up animal hair Periodically clean the mini turbo brush as fol lows Slacken the screws on the base of th...

Страница 10: ...C CO ON NT TR RO OL L B BA AT TT TE ER RY Y THE BATTERY IS NOT SUPPLIED WITH THE PRODUCT In order to work the remote control handle needs to be powered by a 12V type MN21 bat tery The duration of the...

Страница 11: ...NOTE...

Отзывы: