Warning: make the drying cycle with the
water container empty.

The drying cycle eliminates possible water
particles present in the filters and in the suc-
tion tubes of the container (

5

). The purpose

of this process is to avoid interventions of
the humidity sensor, which interrupts the op-
eration of the appliance.
The humidity sensor acts in protection of the
Hepa filter preventing humidity particles from
reaching it, damaging its function.
• Move the two air outlet filter grill opening

levers (

18

) at the same time by pushing

them towards the inside (fig.15) so as to
allow the air outlet filter grill (

17

) to un-

hook. 

• Remove the Hepa filter (

19

) as described

in the "Cleaning or replacing the Hepa fil-
ter" paragraph.

• Remove the back sponge filter (

19a

).

• Connect the supply cable plug (

27

) to the

mains.

• The first stage of the suction power indica-

tor lights (

13

) on the handle will start to

flash.

• To reactivate the appliance, keep the

mains ON/OFF switch (

11

) pushed until

the machine reaches the maximum speed.

• The appliance will keep on working as

long as the humidity sensor feels the pres-
ence of water in the circuit.

• When the sensor no longer feels water in

the circuits of the appliance, it will auto-
matically go to the stand-by position and
the indicator lights (

13

) will start to flash.

• Put the Hepa filter (

19

) and the air outlet

filter grill (

17

) back in place.

• If you want to use the appliance again, fill

the water container (

5

) as indicated in the

"Preparation for use" paragraph, other-
wise store the appliance with the container
(

5

) empty.

H

H

H

H

U

U

U

U

M

M

M

M

II

II

D

D

D

D

II

II

T

T

T

T

Y

Y

Y

Y

S

S

S

S

E

E

E

E

N

N

N

N

S

S

S

S

O

O

O

O

R

R

R

R

• If the sensor measures some humidity, the

machine will stop and the 4 lights on the
indicator lights (

13

) will start to flash alter-

nately first to last and viceversa.

• To reactivate the appliance, keep the

mains ON/OFF switch (

11

) pushed until

the machine reaches the maximum speed.

• The appliance will keep on working as

long as the humidity sensor feels the pres-
ence of water in the circuit.

• When the sensor no longer feels water in

the circuits of the appliance, it will auto-
matically go to the stand-by position and
the indicator light (

13

) will start to flash.

• Reassemble the Hepa filter (

19

) and the

air outlet filter grill (

17

), inserting first the

two pins (

18a

) into the locking holes (

18b

)

(fig.16).

Warning: make the drying cycle with the
water container empty.

U

U

U

U

S

S

S

S

II

II

N

N

N

N

G

G

G

G

  

  

T

T

T

T

O

O

O

O

O

O

O

O

L

L

L

L

S

S

S

S

Tools may be connected directly to the hose
(

D

) or to the telescopic tube (

A

).

Using the telescopic tube (A)

The tube is about 60 cm long when closed, 1
m when extended to its greatest length. To
increase or decrease length, press the catch
positioned as shown in fig. 6 and extend or
reduce length as desired.

Using the joker brush (M)*

The Joker brush may be used to vacuum up
solids or a limited amount of liquids on any
kind of surface.

Using the parquet accessory (N)* 

Position the Joker brush (

M

) on the parquet

accessory (

N

) as shown in figure 17. Apply

the tool to the brush, following the direction
of the arrow so that it is aligned properly and
they connect together.
To release the parquet accessory from the
Joker brush, pull the two levers on the sides
of the frame outward and lift the brush
(fig.18).

* (optional for mod. AS800)

Using the universal brush (B)

Connect the brush to the telescopic tube. If
you move the selector on the brush (

B1

)

Lecologico Compact  AS800 - AS801

43

lecologico as800-801 -1m01.qxp  21/04/2006  11.49  Pagina 43

Содержание LECOLOGICO AS 801

Страница 1: ...compact AS 801 compact AS 801...

Страница 2: ...4 1 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18 Fig 19 Fig 20 Fig 21 Lecologico AS800 AS801 M0S07336 Ediz 1M05...

Страница 3: ...M N 5 A 27 18b 19a 19 18 18a 17 18 3 4 16 1 11 12 13 14 15 10 2 9 8 7 21 22 23 24 25 26 20 6 5 L F I A G J H B B1 C E D A1 1M05...

Страница 4: ...et filter grill 18b Locking holes for air outlet filter grill 19 Hepa filter 19a Back sponge filter 20 EcoActive Filter water filter group 21 Filter cage cover 22 Square sponge filters 23 Shaped spong...

Страница 5: ...What is EcoActive Filter EcoActive Filter is the green heart of Lecologico and consists of a revolutionary water filter The EcoActive Filter employs the natural purifying strength of water to catch t...

Страница 6: ...tainer full of water Never immerse the appliance the cable or the plugs in water or another liquid Use of the appliance in places where there is a danger of explosions is prohibited Do not use the pro...

Страница 7: ...to an appropriate collection facility at the end of its useful lifespan Appropriate separate collection to permit re cycling treatment and environmentally com patible disposal helps prevent negative i...

Страница 8: ...s off fig 12 Divide all the components as described in the key and then rinse them under running water if the sponge filter is damaged re place it by contacting a Polti Authorized Service Centre Befor...

Страница 9: ...T T T TY Y Y Y S S S SE E E EN N N NS S S SO O O OR R R R If the sensor measures some humidity the machine will stop and the 4 lights on the indicator lights 13 will start to flash alter nately first...

Страница 10: ...eful to accompany it during winding G G G GE E E EN N N NE E E ER R R RA A A AL L L L M M M MA A A AI I I IN N N NT T T TE E E EN N N NA A A AN N N NC C C CE E E E Always make sure the appliance is un...

Страница 11: ...e the filter even before the 100 hours E E E EL L L LE E E EC C C CT T T TR R R RI I I IC C C CA A A AL L L L S S S SA A A AF F F FE E E ET T T TY Y Y Y No earth required Ensure the mains voltage suit...

Страница 12: ...he suction switches off during use and the 4 indicator lights flash simultaneously Intervention of the humidity sensor because the filters and tubes are not dry enough Intervention of the humidity sen...

Страница 13: ...NOTE 47...

Отзывы: