Reset command timeout
Arguments
None
Response
None
Arduino library
void resetCommandTimeout()
Command encoding:
0xF5
Description:
This command resets the command timeout, which means that if the command timeout feature
is enabled, this command prevents the timeout from occurring for some time. (The command
timeout is also reset by every other command documented here.) The command timeout feature
is documented in
.
Treatment of unrecognized and invalid bytes
If the Motoron receives a byte with a most significant bit of 1 while it was expecting a data byte for a
command, the command is canceled and the Motoron reports a serial protocol error.
If the Motoron receives a byte with a most significant bit of 1 that is not a recognized command byte,
it will usually report a protocol error. However, bytes 0x80, 0xFE, and 0xFF are ignored, and 0xAA is
a reserved command byte that should not be used during normal operation.
If the Motoron receives a byte with a most significant bit of 0 while it is not expecting a data byte for a
command, it ignores the byte.
Pololu Motoron Motor Controller User’s Guide
© 2001–2022 Pololu Corporation
9. Command reference
Page 65 of 67