22
It means change present status.
It is only allowed to use one channel and can not be changed by Channel Selector when active
Channel lock out function.
Do again the above steps to turn back.
Low Battery Alert
1. Working in Voltage higher 6.5 V
2. Transmit and receive working, but red indicator flashes when voltage lower than 6.5V, but
higher than 6.3V (Battery shows 1 Grid)
3. Voltage higher than 6.1V but lower than 6.3V (battery is blank), Receive working, alarm “Di
Di” by every 20 seconds; Transmit working, but red indicator flashes.
4. Voltage lower than 6.1V, receive working, alarm every 2 0 seconds, but can not transmitting.