Interval
For combustion gas fans: Func-
tional test of the bypass for the
frequency converter and all elec-
trical components
Every 6 months
Check the direction of rotation
Every 6 months
Check the flexible connections
Once a year
Check the flywheel for imbal-
ance
Once a year
Check the safety devices to
make sure they are functional
Once a year
Re-lubricate the bearing
Once a month
Check the V-belt for damage,
check the tension and alignment
Once a year
Check the fan for external signs
of damage, soiling, corrosion
Every 6 months
Check the motor for external
signs of damage, soiling, corro-
sion
Every 6 months
Check the motor bearing for
noises
Once a year
Check that the connection termi-
nals are firmly in place
Once a year
Check the voltage and current
strength
Once a year
8.6 Spare parts
Order according to the order number or type label details of the
manufacturer. Please contact the manufacturer.